Optimization of Placement of Continuous Air Monitors in a Radiological Facility

Abstract The airborne concentration of radioactive materials in radiological facilities is primarily influenced by the ventilation system, air purification system, and emission sources. Continuous Air Monitors (CAMs) are installed in these facilities to monitor the activity concentration of radioactive aerosols during both routine operations and any malfunctioning conditions. Typically, CAM placement is determined by the direction of maximum airflow. However, aerosols do not always adhere to the behaviour of airstreams, raising concerns about the suitability of CAM placement. To address this issue, this study employs software that integrates aerosol dynamics with computational fluid dynamics to calculate the CAM Placement Parameter. This parameter is derived from the peak aerosol concentration and the lag time to reach the specified CAM location, indicating the relative merit of positioning CAMs in a radiological facility under varying ventilation rates. The findings suggest that the coupled aerosol-fluid dynamics model accurately predicts the optimal placement of CAMs in workplace environments, thereby minimizing occupational exposure.

Authors

Institutions

Publication Details

Journal
Aerosol Science and Engineering
Published
2024-11-15
DOI
https://doi.org/10.1007/s41810-024-00268-y
Primary Topic
Graphite, nuclear technology, radiation studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization of Placement of Continuous Air Monitors in a Radiological Facility

M.S. Kulkarni, Manish Joshi, S. Anand, Joy Chakraborty et al.
Aerosol Science and Engineering
Graphite, nuclear technology, radiation studies
article

Optimization of Placement of Continuous Air Monitors in a Radiological Facility

M.S. Kulkarni, Manish Joshi, S. Anand, Joy Chakraborty, M. K. Sureshkumar
article en

Abstract

Abstract The airborne concentration of radioactive materials in radiological facilities is primarily influenced by the ventilation system, air purification system, and emission sources. Continuous Air Monitors (CAMs) are installed in these facilities to monitor the activity concentration of radioactive aerosols during both routine operations and any malfunctioning conditions. Typically, CAM placement is determined by the direction of maximum airflow. However, aerosols do not always adhere to the behaviour of airstreams, raising concerns about the suitability of CAM placement. To address this issue, this study employs software that integrates aerosol dynamics with computational fluid dynamics to calculate the CAM Placement Parameter. This parameter is derived from the peak aerosol concentration and the lag time to reach the specified CAM location, indicating the relative merit of positioning CAMs in a radiological facility under varying ventilation rates. The findings suggest that the coupled aerosol-fluid dynamics model accurately predicts the optimal placement of CAMs in workplace environments, thereby minimizing occupational exposure.

Aerosol Science and EngineeringVol. 9(3)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN)
Bhabha Atomic Research Centre
Openalex Percentile: Top 87%
Graphite, nuclear technology, radiation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization of Placement of Continuous Air Monitors in a Radiological Facility — M.S. Kulkarni, Manish Joshi, et al. · Aerosol Science and Engineering (2024) | TGRS Research Map | TGRS