Peak hip external rotation torque and single-rater reliability is influenced by measurement position in the ISOMED2000

Measurement of hip external rotation strength (ERS) is important for preventive and rehabilitative purposes. ERS can be measured in 3 different positions in the isokinetic dynamometer ISOMED2000. However, it is not clear whether these measurement positions effect ERS nor if these positions are reliable in the ISOMED2000. Hence, the purpose of this study was to compare ERS in these positions, the reliability and the agreement. A cross-sectional design was conducted to compare measurement positions and a test-retest design to assess intra-rater reliability and agreement. Twenty-four healthy, physically active athletes participated in the study. Peak isometric torque was measured in the ISOMED in prone, supine, and side-lying position across two sessions on one day. Differences between positions were evaluated with the Wilcoxon-signed-rank test and cliff's delta. Reliability was assessed via intraclass correlation. Agreement was determined using the standard error of measurement (SEM), minimal detectable change (MDC), and Bland-Altman analysis (BAA). Results indicated a significant influence of measurement position on ERS (p < 0.001) with high effect sizes (>0.74). Reliability and agreement were high in all positions, but highest for the side-lying position (ICC = 0.90 [0.78, 0.96]; SEM = 0.08; MDC = 0.23; BAA_bias = 3.4 %, BAA_loA = 37 %). There were only poor to moderate correlations between measurement positions. These findings suggest that measurement position significantly affects ERS. Furthermore, the effect varies across individuals indicating that normative values cannot be used interchangeably or be adapted across positions. In diagnostic testing ERS should be measured in the same position, but preferably in the side-lying position.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanics
Published
2024-11-15
DOI
https://doi.org/10.1016/j.jbiomech.2024.112430
Citations
2
Primary Topic
Lower Extremity Biomechanics and Pathologies
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Peak hip external rotation torque and single-rater reliability is influenced by measurement position in the ISOMED2000

Wilfried Alt, Dieter Bubeck, Tobias Siebert, Christina Frese et al.
2 citations
Journal of Biomechanics
Lower Extremity Biomechanics and Pathologies
0.37
article

Peak hip external rotation torque and single-rater reliability is influenced by measurement position in the ISOMED2000

Wilfried Alt, Dieter Bubeck, Tobias Siebert, Christina Frese, Iris Astner, Daniel Sitte
article en
2 citations

Abstract

Measurement of hip external rotation strength (ERS) is important for preventive and rehabilitative purposes. ERS can be measured in 3 different positions in the isokinetic dynamometer ISOMED2000. However, it is not clear whether these measurement positions effect ERS nor if these positions are reliable in the ISOMED2000. Hence, the purpose of this study was to compare ERS in these positions, the reliability and the agreement. A cross-sectional design was conducted to compare measurement positions and a test-retest design to assess intra-rater reliability and agreement. Twenty-four healthy, physically active athletes participated in the study. Peak isometric torque was measured in the ISOMED in prone, supine, and side-lying position across two sessions on one day. Differences between positions were evaluated with the Wilcoxon-signed-rank test and cliff's delta. Reliability was assessed via intraclass correlation. Agreement was determined using the standard error of measurement (SEM), minimal detectable change (MDC), and Bland-Altman analysis (BAA). Results indicated a significant influence of measurement position on ERS (p < 0.001) with high effect sizes (>0.74). Reliability and agreement were high in all positions, but highest for the side-lying position (ICC = 0.90 [0.78, 0.96]; SEM = 0.08; MDC = 0.23; BAA_bias = 3.4 %, BAA_loA = 37 %). There were only poor to moderate correlations between measurement positions. These findings suggest that measurement position significantly affects ERS. Furthermore, the effect varies across individuals indicating that normative values cannot be used interchangeably or be adapted across positions. In diagnostic testing ERS should be measured in the same position, but preferably in the side-lying position.

Journal of BiomechanicsVol. 177
University of Stuttgart (DE)
Deutsche Forschungsgemeinschaft
Affordable and clean energy
Openalex Percentile: Top 42%
Lower Extremity Biomechanics and Pathologies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.