Rosuvastatin calcium electrochemical sensor based on a sulfur doped graphitic carbon nitride modified glassy carbon electrode: A metal free analysis approach
• S-g-C 3 N 4 was prepared using Melamine and sulfur powder via Thermal polymerization method. • S-g-C 3 N 4 has been used as metal-free electrochemical electrode for the detection of Rosuvastatin calcium (ROS). • Analytical studies reveals a significant decrease in impedance, indicating improved conductivity. • S-g-C 3 N 4 @GCE exhibited outstanding performance with an extremely low detection limit of 0.10 µM. This study explored the benefits of heteroatom doping to enhance sensor efficiency by developing a low-cost, metal-free electrochemical sensor. Melamine and sulfur powders were used as precursors in a one-step thermal polymerization technique to produce sulfur-doped graphitic carbon nitride (S-g-C 3 N 4 ). The structural and morphological properties of the synthesized materials were extensively analyzed using several techniques, including XRD, XPS, SEM, HRTEM, and EIS. The results show a significant decrease in impedance, indicating improved conductivity. In addition, the doping approach significantly enhanced the reduction in current receptivity compared to unmodified graphitic carbon nitride (g-C 3 N 4 ). We used differential pulse voltammetry (DPV) and cyclic voltammetry (CV) to instigate the electro-oxidation of Rosuvastatin calcium (ROS), as well as concentration-dependence and selectivity studies, using a sulfur-doped graphitic carbon nitride-modified glassy carbon electrode (S-g-C 3 N 4 @GCE). S-g-C 3 N 4 @GCE exhibited outstanding performance with an extremely low detection limit of 0.10 µM and a wide linear range (5–100 µM), highlighting its potential for highly sensitive assays and its exceptional capability to operate over a broad ROS concentration range.
Authors
- Ahmad Umar (ORCID: https://orcid.org/0000-0002-8626-1564)
- M. Shaheer Akhtar (ORCID: https://orcid.org/0000-0001-7698-2619)
- Manu Sharma (ORCID: https://orcid.org/0000-0002-1260-5416)
- Yongho Seo (ORCID: https://orcid.org/0000-0002-5695-5493)
- Kamal Kishor Thakur (ORCID: https://orcid.org/0000-0001-6728-4595)
- Sheikh A. Akbar (ORCID: https://orcid.org/0000-0003-3567-274X)
- Sunil Kumar (ORCID: https://orcid.org/0000-0001-9429-3809)
- Ahmed A. Ibrahim (ORCID: https://orcid.org/0000-0003-1365-8226)
- Dilbag Singh
Institutions
- Chandigarh University (IN)
- Central University of Himachal Pradesh (IN)
- La Trobe University (AU)
- Sejong University (KR)
- Najran University (SA)
- The Ohio State University (US)
- Jeonbuk National University (KR)
Publication Details
- Journal
- Microchemical Journal
- Published
- 2024-11-15
- DOI
- https://doi.org/10.1016/j.microc.2024.112177
- Citations
- 2
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.42