Impact of microwave phase noise on diamond quantum sensing

Precision optical measurements of the electron-spin precession of nitrogen-vacancy (NV) centers in diamond form the basis of numerous applications. The most sensitivity-demanding applications, such as femtotesla magnetometry, require the ability to measure changes in GHz spin transition frequencies at the sub-millihertz level, corresponding to a fractional resolution of better than 10<sup>-12</sup>. Here we study the impact of microwave (MW) phase noise on the response of an NV sensor. Fluctuations of the phase of the MW waveform cause undesired rotations of the NV spin state. These fluctuations are imprinted in the optical readout signal and, left unmitigated, are indistinguishable from magnetic-field noise. We show that the phase noise of several common commercial MW generators results in an effective <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mtext>pT</mml:mtext> <mml:mspace></mml:mspace> <mml:msup><mml:mrow><mml:mtext>s</mml:mtext></mml:mrow> <mml:mrow><mml:mn>1</mml:mn> <mml:mo>/</mml:mo> <mml:mn>2</mml:mn></mml:mrow> </mml:msup> </mml:math> -range noise floor that varies with the MW carrier frequency and the detection frequency of the pulse sequence. The data are described by a frequency-domain model incorporating the MW phase-noise spectrum and the filter-function response of the sensing protocol. For controlled injection of white and random-walk phase noise, the observed NV magnetic noise floor is described by simple analytic expressions that accurately capture the scaling with pulse sequence length and the number of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>π</mml:mi></mml:math> pulses. We outline several strategies to suppress the impact of MW phase noise and implement a version, based on gradiometry, that realizes a > 10-fold suppression. Our study highlights an important challenge in the pursuit of sensitive diamond quantum sensors and is applicable to other qubit systems with a large transition frequency.

Authors

Institutions

Publication Details

Journal
Physical Review Research
Published
2024-11-15
DOI
https://doi.org/10.1103/physrevresearch.6.043148
Citations
3
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.35

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of microwave phase noise on diamond quantum sensing

Víctor M. Acosta, Andris Bērziņš, Maziar Saleh Ziabari, Pauli Kehayias et al.
3 citations
Physical Review Research
Diamond and Carbon-based Materials Research
0.35
article

Impact of microwave phase noise on diamond quantum sensing

Víctor M. Acosta, Andris Bērziņš, Maziar Saleh Ziabari, Pauli Kehayias, Jānis Šmits, Andrey Jarmola, Joshua T. Damron, Ilja Fescenko, John F. Barry, Yaser Silani, Bryan A. Richards
article en
3 citations

Abstract

Precision optical measurements of the electron-spin precession of nitrogen-vacancy (NV) centers in diamond form the basis of numerous applications. The most sensitivity-demanding applications, such as femtotesla magnetometry, require the ability to measure changes in GHz spin transition frequencies at the sub-millihertz level, corresponding to a fractional resolution of better than 10<sup>-12</sup>. Here we study the impact of microwave (MW) phase noise on the response of an NV sensor. Fluctuations of the phase of the MW waveform cause undesired rotations of the NV spin state. These fluctuations are imprinted in the optical readout signal and, left unmitigated, are indistinguishable from magnetic-field noise. We show that the phase noise of several common commercial MW generators results in an effective <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mtext>pT</mml:mtext> <mml:mspace></mml:mspace> <mml:msup><mml:mrow><mml:mtext>s</mml:mtext></mml:mrow> <mml:mrow><mml:mn>1</mml:mn> <mml:mo>/</mml:mo> <mml:mn>2</mml:mn></mml:mrow> </mml:msup> </mml:math> -range noise floor that varies with the MW carrier frequency and the detection frequency of the pulse sequence. The data are described by a frequency-domain model incorporating the MW phase-noise spectrum and the filter-function response of the sensing protocol. For controlled injection of white and random-walk phase noise, the observed NV magnetic noise floor is described by simple analytic expressions that accurately capture the scaling with pulse sequence length and the number of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:mi>π</mml:mi></mml:math> pulses. We outline several strategies to suppress the impact of MW phase noise and implement a version, based on gradiometry, that realizes a > 10-fold suppression. Our study highlights an important challenge in the pursuit of sensitive diamond quantum sensors and is applicable to other qubit systems with a large transition frequency.

Physical Review ResearchVol. 6(4)
Oak Ridge National Laboratory (US), University of New Mexico (US), University of California System (US), Sandia National Laboratories (US), MMR Technologies (United States) (US), MIT Lincoln Laboratory (US), Massachusetts Institute of Technology (US), University of Latvia (LV), University of California, Berkeley (US)
National Science Foundation, National Institutes of Health, Division of Chemistry
Openalex Percentile: Top 43%
Diamond and Carbon-based Materials Research
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.