Determination of the gas-liquid reaction kinetic for sulfur dioxide absorption in sodium chlorite aqueous solutions

• Falling film contactors improve the gas-liquid reaction kinetics estimation accuracy. • Absorbing solution pH strongly influences oxidation mechanisms. • The AOM results in faster reaction kinetics. • Gas-liquid reaction rate increases significantly with temperature. • The kinetic model correctly predicts data from the literature. This study is part of the research activities devoted to the development of new gas-cleaning technologies required to minimize the emissions factors of sulfur compounds in chemical industries and power plants. Among flue gas desulfurization (FGD) processes, wet scrubbing with oxidizing chemicals, e.g. sodium chlorite (NaClO 2 ) has appeared as a viable option for different applications. The present work aims to study the absorption kinetics of the gas-liquid reaction between sulfur dioxide (SO 2 ) and NaClO 2 , in a lab-scale falling-film absorber, investigating the effects of the main process parameters: liquid and gas flow rates, SO 2 gas-phase concentration, NaClO 2 liquid-phase concentration, solution pH and process temperature. The experimental activity aims to determine the Enhancement Factor ( E L ) to develop a kinetic model for reactive absorption. To this end, kinetic parameters are calculated from experiments using the Danckwerts equation for a pseudo-second-order reaction kinetic, determining a maximum prediction error of ±20% compared to the experimental data. Experimental data available in the literature on pilot-scale oxidative FGD scrubbers using chlorite are used to test the validity and robustness of the kinetic model. The kinetic model is able to predict the data with good accuracy within a prediction error range of ±30%.

Authors

Institutions

Publication Details

Journal
Chemical Engineering Science
Published
2024-11-15
DOI
https://doi.org/10.1016/j.ces.2024.120938
Citations
2
Primary Topic
Industrial Gas Emission Control
Type
article
Field-Weighted Citation Impact
0.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the gas-liquid reaction kinetic for sulfur dioxide absorption in sodium chlorite aqueous solutions

Alessandro Erto, Francesco Di Natale, Luigi Santamaria Amato, D. Flagiello et al.
2 citations
Chemical Engineering Science
Industrial Gas Emission Control
0.43
article

Determination of the gas-liquid reaction kinetic for sulfur dioxide absorption in sodium chlorite aqueous solutions

Alessandro Erto, Francesco Di Natale, Luigi Santamaria Amato, D. Flagiello, Amedeo Lancia, D. Ricchiari
article en
2 citations

Abstract

• Falling film contactors improve the gas-liquid reaction kinetics estimation accuracy. • Absorbing solution pH strongly influences oxidation mechanisms. • The AOM results in faster reaction kinetics. • Gas-liquid reaction rate increases significantly with temperature. • The kinetic model correctly predicts data from the literature. This study is part of the research activities devoted to the development of new gas-cleaning technologies required to minimize the emissions factors of sulfur compounds in chemical industries and power plants. Among flue gas desulfurization (FGD) processes, wet scrubbing with oxidizing chemicals, e.g. sodium chlorite (NaClO 2 ) has appeared as a viable option for different applications. The present work aims to study the absorption kinetics of the gas-liquid reaction between sulfur dioxide (SO 2 ) and NaClO 2 , in a lab-scale falling-film absorber, investigating the effects of the main process parameters: liquid and gas flow rates, SO 2 gas-phase concentration, NaClO 2 liquid-phase concentration, solution pH and process temperature. The experimental activity aims to determine the Enhancement Factor ( E L ) to develop a kinetic model for reactive absorption. To this end, kinetic parameters are calculated from experiments using the Danckwerts equation for a pseudo-second-order reaction kinetic, determining a maximum prediction error of ±20% compared to the experimental data. Experimental data available in the literature on pilot-scale oxidative FGD scrubbers using chlorite are used to test the validity and robustness of the kinetic model. The kinetic model is able to predict the data with good accuracy within a prediction error range of ±30%.

Chemical Engineering ScienceVol. 303
Eurac Research (IT), University of Naples Federico II (IT)
Clean water and sanitation
Openalex Percentile: Top 41%
Industrial Gas Emission Control
0.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.