Performance evaluation of the Specific Reveal system for rapid antibiotic susceptibility testing from positive blood cultures containing Gram-negative pathogens

Rapid antimicrobial drug administration is crucial for the efficient treatment of sepsis or septic shock, but empirical therapy is limited by the increasing prevalence of multidrug-resistant bacteria. Thus, rapid and reliable antimicrobial susceptibility testing (AST) is needed to start appropriate antimicrobial drug administration as quickly as possible. In the present study, we evaluated the performance of the Reveal rapid AST system. From February to April 2021, 102 positive blood culture bottles (BCBs) from hospitalized patients with bacteremia caused by Gram-negative bacteria were included in the study. All isolates were tested by the Reveal system directly from the positive BCBs in comparison to the DxM MicroScan WalkAway. Essential agreement (EA) and category agreement (CA) were high with 98.5% and 97.1%, respectively. We also determined the susceptibility of 10 highly resistant CDC & FDA AR strains in duplicate. Here, EA was 99.6% and CA 97.9%. The average time to result by Reveal was 5.4 h ± 1.2 h compared to an average of 16 h by DxM MicroScan WalkAway for clinical strains and 3.8 h ± 1.2 h for more resistant CDC & FDA AR strains. Susceptibility determination with the Reveal rapid AST system directly from positive BCBs is for the frequently represented bug-drug combinations a reliable and accurate approach, meeting the European ISO guideline for the performance of AST systems. Moreover, AST directly from blood cultures performed with the Reveal system saves time when compared to the conventional AST, as no subculturing is needed and time to result is very short.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Microbiology
Published
2024-11-15
DOI
https://doi.org/10.1128/jcm.00692-24
Citations
7
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
2.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance evaluation of the Specific Reveal system for rapid antibiotic susceptibility testing from positive blood cultures containing Gram-negative pathogens

Greta Flüh, Barbara Körber-Irrgang, Hilmar Wisplinghoff, Kim Chi Vo et al.
7 citations
Journal of Clinical Microbiology
Bacterial Identification and Susceptibility Testing
2.67
article

Performance evaluation of the Specific Reveal system for rapid antibiotic susceptibility testing from positive blood cultures containing Gram-negative pathogens

Greta Flüh, Barbara Körber-Irrgang, Hilmar Wisplinghoff, Kim Chi Vo, Pragya Singh, Ute Aurbach, Nathalie Jazmati, Jörg Gielen, A. Krüger
article en
7 citations

Abstract

Rapid antimicrobial drug administration is crucial for the efficient treatment of sepsis or septic shock, but empirical therapy is limited by the increasing prevalence of multidrug-resistant bacteria. Thus, rapid and reliable antimicrobial susceptibility testing (AST) is needed to start appropriate antimicrobial drug administration as quickly as possible. In the present study, we evaluated the performance of the Reveal rapid AST system. From February to April 2021, 102 positive blood culture bottles (BCBs) from hospitalized patients with bacteremia caused by Gram-negative bacteria were included in the study. All isolates were tested by the Reveal system directly from the positive BCBs in comparison to the DxM MicroScan WalkAway. Essential agreement (EA) and category agreement (CA) were high with 98.5% and 97.1%, respectively. We also determined the susceptibility of 10 highly resistant CDC & FDA AR strains in duplicate. Here, EA was 99.6% and CA 97.9%. The average time to result by Reveal was 5.4 h ± 1.2 h compared to an average of 16 h by DxM MicroScan WalkAway for clinical strains and 3.8 h ± 1.2 h for more resistant CDC & FDA AR strains. Susceptibility determination with the Reveal rapid AST system directly from positive BCBs is for the frequently represented bug-drug combinations a reliable and accurate approach, meeting the European ISO guideline for the performance of AST systems. Moreover, AST directly from blood cultures performed with the Reveal system saves time when compared to the conventional AST, as no subculturing is needed and time to result is very short.

Journal of Clinical MicrobiologyVol. 62(12)
Witten/Herdecke University (DE), University of Cologne (DE), Specific Technologies (United States) (US), Longevity Biotech (United States) (US), Laboratory Dr. Wisplinghoff (DE), Specifica (United States) (US), Human Longevity (United States) (US), Institute of Medical Microbiology and Hygiene (DE)
Good health and well-being
Openalex Percentile: Top 10%
Bacterial Identification and Susceptibility Testing
2.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.