A Multi-Optical and Mechanical Compensation Robotic Surgery System Based on Augmented Reality for Endoscopic Neurosurgery

Abstract Endoscopic treatment is a widely employed clinical modality for the rapid reduction of cranial pressure in cases of intracerebral hemorrhage (ICH). We are working to make endoscopic surgery simpler and more effective by providing surgeons with robot and augmented reality (AR). This paper proposes an AR-based multi-optical and mechanical compensation robotic surgical system that can precisely match the virtual hematoma region with the anatomical structures seen under a robot-wielded neuroendoscope. The custom mark unified multi-optical localization system enables optical tracking over a wide range of angles and breadths. The neuroendoscope registration employs a multimodal error compensation approach based on an optical tracking system and the kinematic model of the robotic arm. Utilizing innovative methods, we register patients, medical images, optical localizers, and both neuroendoscopic and robotic coordinate systems, thereby enabling dual-view AR tracking through video-stream fusion. In multimodal error compensation for neuroendoscopic registration, the calibration error is 0.37 mm. The system's performance was evaluated through ten phantom experiments, showing the registration accuracy of 0.39±0.10 mm, optical localizer AR fusion accuracy of 3.30±1.08%, neuroendoscope AR fusion accuracy of 5.22±1.02%, and optical localizer AR average distance and angle accuracies of 1.73±0.21 mm and 0.38±0.13 deg, respectively. The AR-based robotic surgical system (ARSS) overlays virtual lesions onto the current endoscopic view of the real lesions in real-time, which can help surgeons to localize lesions hidden deep in tissue by an endoscopy. It is anticipated that the ARSS will reduce surgeon fatigue and improve the intuitiveness of endoscopic surgery.

Authors

Institutions

Publication Details

Journal
Journal of Medical Devices
Published
2024-11-15
DOI
https://doi.org/10.1115/1.4067172
Citations
2
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
1.15
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Multi-Optical and Mechanical Compensation Robotic Surgery System Based on Augmented Reality for Endoscopic Neurosurgery

Shan Jiang, Zeyang Zhou, Shixing Ma, Zhiyong Yang et al.
2 citations
Journal of Medical Devices
Surgical Simulation and Training
1.15
article

A Multi-Optical and Mechanical Compensation Robotic Surgery System Based on Augmented Reality for Endoscopic Neurosurgery

Shan Jiang, Zeyang Zhou, Shixing Ma, Zhiyong Yang, Yuhua Li, Zhongguo Lin
article en
2 citations

Abstract

Abstract Endoscopic treatment is a widely employed clinical modality for the rapid reduction of cranial pressure in cases of intracerebral hemorrhage (ICH). We are working to make endoscopic surgery simpler and more effective by providing surgeons with robot and augmented reality (AR). This paper proposes an AR-based multi-optical and mechanical compensation robotic surgical system that can precisely match the virtual hematoma region with the anatomical structures seen under a robot-wielded neuroendoscope. The custom mark unified multi-optical localization system enables optical tracking over a wide range of angles and breadths. The neuroendoscope registration employs a multimodal error compensation approach based on an optical tracking system and the kinematic model of the robotic arm. Utilizing innovative methods, we register patients, medical images, optical localizers, and both neuroendoscopic and robotic coordinate systems, thereby enabling dual-view AR tracking through video-stream fusion. In multimodal error compensation for neuroendoscopic registration, the calibration error is 0.37 mm. The system's performance was evaluated through ten phantom experiments, showing the registration accuracy of 0.39±0.10 mm, optical localizer AR fusion accuracy of 3.30±1.08%, neuroendoscope AR fusion accuracy of 5.22±1.02%, and optical localizer AR average distance and angle accuracies of 1.73±0.21 mm and 0.38±0.13 deg, respectively. The AR-based robotic surgical system (ARSS) overlays virtual lesions onto the current endoscopic view of the real lesions in real-time, which can help surgeons to localize lesions hidden deep in tissue by an endoscopy. It is anticipated that the ARSS will reduce surgeon fatigue and improve the intuitiveness of endoscopic surgery.

Journal of Medical DevicesVol. 19(2)
Tianjin University of Technology and Education (CN), Tianjin University (CN), Tianjin haihe hospital (CN)
Openalex Percentile: Top 19%
Surgical Simulation and Training
1.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.