Optimization and characterization of a PCF-based SPR sensor for enhanced sensitivity and reliability in diverse chemical and biological applications

This paper presents the meticulous design and characterization of a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor, analyzed using finite element method (FEM) simulations. The sensor’s superior performance is demonstrated by its exceptional sensitivity to minute changes in the refractive index (RI) of various analytes. The optimized structure reveals a peak resonance at 0.78898 µm with a maximum confinement loss of 546.34 dB/cm. Detailed investigations show resonance wavelength red shifts of up to 0.93% with a 5% increase in air hole diameter and blue shifts of up to 0.88% with a 5% decrease. Additionally, variations in the plasmonic gold layer thickness result in resonance shifts of up to 0.76% longer or 0.87% shorter wavelengths. The sensor achieves remarkable wavelength sensitivity (WS) of up to 13,000 nm/RIU and amplitude sensitivity (AS) of up to 1538.90RIU −1 , underscoring its high precision in detecting analyte concentration changes. The design’s robustness against fabrication errors, evidenced by minimal variations in resonance characteristics, highlights its practical reliability. Furthermore, the use of a polynomial regression model with an R 2 value near unity accurately approximates the relationship between resonance wavelength and analyte RI, ensuring precise sensing capabilities without overfitting. Comparative analysis with existing designs confirms the sensor’s superior performance, rendering it highly suitable for a wide range of applications, including biosensing of glucose, water contaminated by cholera germs, mucosa of the human intestine, important components of human blood, and detection of chemicals like acetone, ethanol, benzene, propanol, glycerol, and expired transformer oil.

Authors

Publication Details

Journal
Journal of the Optical Society of America B
Published
2024-11-15
DOI
https://doi.org/10.1364/josab.537519
Citations
4
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization and characterization of a PCF-based SPR sensor for enhanced sensitivity and reliability in diverse chemical and biological applications

N. R. Das, Asish K. Mukhopadhyay, Santu Sarkar, Subhadeep Mukherjee
4 citations
Journal of the Optical Society of America B
Analytical Chemistry and Sensors
1.16
article

Optimization and characterization of a PCF-based SPR sensor for enhanced sensitivity and reliability in diverse chemical and biological applications

N. R. Das, Asish K. Mukhopadhyay, Santu Sarkar, Subhadeep Mukherjee
article en
4 citations

Abstract

This paper presents the meticulous design and characterization of a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor, analyzed using finite element method (FEM) simulations. The sensor’s superior performance is demonstrated by its exceptional sensitivity to minute changes in the refractive index (RI) of various analytes. The optimized structure reveals a peak resonance at 0.78898 µm with a maximum confinement loss of 546.34 dB/cm. Detailed investigations show resonance wavelength red shifts of up to 0.93% with a 5% increase in air hole diameter and blue shifts of up to 0.88% with a 5% decrease. Additionally, variations in the plasmonic gold layer thickness result in resonance shifts of up to 0.76% longer or 0.87% shorter wavelengths. The sensor achieves remarkable wavelength sensitivity (WS) of up to 13,000 nm/RIU and amplitude sensitivity (AS) of up to 1538.90RIU −1 , underscoring its high precision in detecting analyte concentration changes. The design’s robustness against fabrication errors, evidenced by minimal variations in resonance characteristics, highlights its practical reliability. Furthermore, the use of a polynomial regression model with an R 2 value near unity accurately approximates the relationship between resonance wavelength and analyte RI, ensuring precise sensing capabilities without overfitting. Comparative analysis with existing designs confirms the sensor’s superior performance, rendering it highly suitable for a wide range of applications, including biosensing of glucose, water contaminated by cholera germs, mucosa of the human intestine, important components of human blood, and detection of chemicals like acetone, ethanol, benzene, propanol, glycerol, and expired transformer oil.

Journal of the Optical Society of America BVol. 42(1)
Affordable and clean energy
Openalex Percentile: Top 24%
Analytical Chemistry and Sensors
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Optimization and characterization of a PCF-based SPR sensor for enhanced sensitivity and reliability in diverse chemical and biological applications — N. R. Das, Asish K. Mukhopadhyay, et al. · Journal of the Optical Society of America B (2024) | TGRS Research Map | TGRS