Mechanical Characteristics of Grillage Root Foundation for High-Voltage Tower Under Horizontal Conditions

In response to the issue of reduced horizontal bearing capacity due to inadequate compaction of backfill soil in traditional grillage foundations, a novel grillage root foundation is proposed in this study. That is, the root is introduced into undisturbed soil at a traditional grillage foundation base plate. To assess the applicability of this innovative foundation under horizontal loading conditions, on-site experimental research was conducted. It was employed to comparatively analyze the load–displacement curves, changes in internal forces of steel components, and the development patterns of soil cracks around the foundation between traditional grillage foundations and various sizes of grillage root foundations subjected to horizontal loading. The results indicate that the horizontal bearing capacity of the grillage root foundation increased by 1.3 times compared to traditional grillage foundations, with economic benefits surpassing those of the traditional counterparts. The determination of the “m” value serves as the proportional coefficient of the horizontal resistance coefficient of the foundation soil, and the synthesis of the reactive force provided by the soil to the roots contribute to enhancements in soil resistance and the horizontal bearing capacity of the foundation. The horizontal load at which cracks appear in the grillage root foundation exceeds that of the traditional metal grillage foundation, with a slower rate of development. Finite element analysis was conducted to optimize the arrangement of roots, maximizing the foundation’s bearing capacity. This research provides certain references in terms of enhancing foundation bearing capacity, reducing ground treatment costs, and promoting sustainable development.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2024-11-15
DOI
https://doi.org/10.3390/buildings14113633
Citations
1
Primary Topic
Geotechnical Engineering and Soil Stabilization
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical Characteristics of Grillage Root Foundation for High-Voltage Tower Under Horizontal Conditions

Huang Xuefeng, Senlin Yang, Jun Yuan, Kun Sun et al.
1 citations
Buildings
Geotechnical Engineering and Soil Stabilization
0.26
article

Mechanical Characteristics of Grillage Root Foundation for High-Voltage Tower Under Horizontal Conditions

Huang Xuefeng, Senlin Yang, Jun Yuan, Kun Sun, Zhanshan Ma, Junjie Wang
article en
1 citations

Abstract

In response to the issue of reduced horizontal bearing capacity due to inadequate compaction of backfill soil in traditional grillage foundations, a novel grillage root foundation is proposed in this study. That is, the root is introduced into undisturbed soil at a traditional grillage foundation base plate. To assess the applicability of this innovative foundation under horizontal loading conditions, on-site experimental research was conducted. It was employed to comparatively analyze the load–displacement curves, changes in internal forces of steel components, and the development patterns of soil cracks around the foundation between traditional grillage foundations and various sizes of grillage root foundations subjected to horizontal loading. The results indicate that the horizontal bearing capacity of the grillage root foundation increased by 1.3 times compared to traditional grillage foundations, with economic benefits surpassing those of the traditional counterparts. The determination of the “m” value serves as the proportional coefficient of the horizontal resistance coefficient of the foundation soil, and the synthesis of the reactive force provided by the soil to the roots contribute to enhancements in soil resistance and the horizontal bearing capacity of the foundation. The horizontal load at which cracks appear in the grillage root foundation exceeds that of the traditional metal grillage foundation, with a slower rate of development. Finite element analysis was conducted to optimize the arrangement of roots, maximizing the foundation’s bearing capacity. This research provides certain references in terms of enhancing foundation bearing capacity, reducing ground treatment costs, and promoting sustainable development.

BuildingsVol. 14(11)
Wuhan Municipal Engineering Design & Research Institute (CN), China Power Engineering Consulting Group (China) (CN), Chongqing Jiaotong University (CN)
Openalex Percentile: Top 43%
Geotechnical Engineering and Soil Stabilization
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.