Prussian blue-doped CaCO<sub>3</sub> nanoparticle-labeled secondary antibodies for electrochemical immunoassay of interleukin-6 with migraine patients

The sensitive and accurate identification of interleukin-6 (IL-6) in biological fluids is essential for assessing migraine due to its role in different physiological and pathological processes. In this study, we designed a simple and feasible electrochemical immunosensing method for the voltammetric measurement of IL-6. The electrochemical immunosensor was fabricated through covalent conjugation of anti-IL-6 capture antibodies on the glassy carbon electrode with a typical carbodiimide coupling method. Anti-IL-6 secondary antibodies were labeled on the surface of Prussian blue-doped CaCO<sub>3</sub> nanoparticles (PBCaNP) <i>via</i> the epoxy-amino reaction. The assay was carried out with a sandwich-type immunoreaction. In the presence of target IL-6, the analyte was sandwiched between the capture antibody and detection antibody. Thereafter, the carried PBCaNP accompanying the secondary antibody could be detected by using square wave voltammetry (SWV). The voltammetric peak current was dependent on the concentration of target IL-6. Under optimum conditions, the electrochemical immunosensor exhibited good analytical properties, and allowed detection of IL-6 within a wide linear range from 0.1 to 1000 pg mL<sup>-1</sup>. The limit of detection was estimated to be 0.078 pg mL<sup>-1</sup> of IL-6 at the 3<i>s</i><sub>B</sub> criterion. An intermediate reproducibility of ≤10.59% was accomplished with batch-to-batch identification, and good anti-interference capacity against other biomolecules was achieved. Importantly, clinical human serum samples obtained from 15 migraine patients were analyzed with the developed electrochemical immunosensors, giving results well-matched with those obtained from the referenced enzyme-linked immunosorbent assay (ELISA) method.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2024-11-15
DOI
https://doi.org/10.1039/d4an01357c
Citations
2
Primary Topic
Advanced Nanomaterials in Catalysis
Type
article
Field-Weighted Citation Impact
0.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prussian blue-doped CaCO3 nanoparticle-labeled secondary antibodies for electrochemical immunoassay of interleukin-6 with migraine patients

Wenhui He, Yin‐Jia Cheng, Zhongbing Chen, Xiaoling Jiang et al.
2 citations
The Analyst
Advanced Nanomaterials in Catalysis
0.23
article

Prussian blue-doped CaCO3 nanoparticle-labeled secondary antibodies for electrochemical immunoassay of interleukin-6 with migraine patients

Wenhui He, Yin‐Jia Cheng, Zhongbing Chen, Xiaoling Jiang, Renhe Lin, Dongzhi Wu
article en
2 citations

Abstract

The sensitive and accurate identification of interleukin-6 (IL-6) in biological fluids is essential for assessing migraine due to its role in different physiological and pathological processes. In this study, we designed a simple and feasible electrochemical immunosensing method for the voltammetric measurement of IL-6. The electrochemical immunosensor was fabricated through covalent conjugation of anti-IL-6 capture antibodies on the glassy carbon electrode with a typical carbodiimide coupling method. Anti-IL-6 secondary antibodies were labeled on the surface of Prussian blue-doped CaCO<sub>3</sub> nanoparticles (PBCaNP) <i>via</i> the epoxy-amino reaction. The assay was carried out with a sandwich-type immunoreaction. In the presence of target IL-6, the analyte was sandwiched between the capture antibody and detection antibody. Thereafter, the carried PBCaNP accompanying the secondary antibody could be detected by using square wave voltammetry (SWV). The voltammetric peak current was dependent on the concentration of target IL-6. Under optimum conditions, the electrochemical immunosensor exhibited good analytical properties, and allowed detection of IL-6 within a wide linear range from 0.1 to 1000 pg mL<sup>-1</sup>. The limit of detection was estimated to be 0.078 pg mL<sup>-1</sup> of IL-6 at the 3<i>s</i><sub>B</sub> criterion. An intermediate reproducibility of ≤10.59% was accomplished with batch-to-batch identification, and good anti-interference capacity against other biomolecules was achieved. Importantly, clinical human serum samples obtained from 15 migraine patients were analyzed with the developed electrochemical immunosensors, giving results well-matched with those obtained from the referenced enzyme-linked immunosorbent assay (ELISA) method.

The AnalystVol. 150(1)
Fujian Medical University (CN), Fuzhou Second Hospital (CN)
Natural Science Foundation of Fujian Province
Openalex Percentile: Top 50%
Advanced Nanomaterials in Catalysis
0.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.