ESR measurement of carbonated hydroxyapatite for dosemeter

We have examined a dosimetry characteristic of carbonate hydroxyapatite (CO3HAp), which is a dental bone graft material. The purpose of this work is to investigate the reproducibility and stability of radiation-induced radicals on CO3HAp samples and assess the feasibility of using these materials as dosemeters. CO3HAp samples were exposed to gamma rays with dose range from 10 to 10 000 Gy. The electron spin resonance (ESR) spectra for irradiated samples were measured. Variation of peak-to-peak amplitude of the ESR signal intensity as a function of absorbed dose for CO3HAp was compared with that for alanine dosemeters, suggesting that the CO3HAp sample has a good linear dose response in the range from 10 to 10 000 Gy as well as does the alanine dosemeters.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-11-01
DOI
https://doi.org/10.1093/rpd/ncae147
Primary Topic
Radiation Effects and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ESR measurement of carbonated hydroxyapatite for dosemeter

Toshitaka Oka, Naotsugu Nagasawa, Hajime Seito, Yoshihiro Kitatsuji et al.
Radiation Protection Dosimetry
Radiation Effects and Dosimetry
article

ESR measurement of carbonated hydroxyapatite for dosemeter

Toshitaka Oka, Naotsugu Nagasawa, Hajime Seito, Yoshihiro Kitatsuji, Eri Yokozuka
article en

Abstract

We have examined a dosimetry characteristic of carbonate hydroxyapatite (CO3HAp), which is a dental bone graft material. The purpose of this work is to investigate the reproducibility and stability of radiation-induced radicals on CO3HAp samples and assess the feasibility of using these materials as dosemeters. CO3HAp samples were exposed to gamma rays with dose range from 10 to 10 000 Gy. The electron spin resonance (ESR) spectra for irradiated samples were measured. Variation of peak-to-peak amplitude of the ESR signal intensity as a function of absorbed dose for CO3HAp was compared with that for alanine dosemeters, suggesting that the CO3HAp sample has a good linear dose response in the range from 10 to 10 000 Gy as well as does the alanine dosemeters.

Radiation Protection DosimetryVol. 200(16-18)
Japan Atomic Energy Agency (JP), National Institutes for Quantum Science and Technology (JP)
Openalex Percentile: Top 76%
Radiation Effects and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

ESR measurement of carbonated hydroxyapatite for dosemeter — Toshitaka Oka, Naotsugu Nagasawa, et al. · Radiation Protection Dosimetry (2024) | TGRS Research Map | TGRS