Abstract 4146203: Ultrasound-Targeted Microbubble Cavitation For The Treatment Of Myocardial Microvascular Obstruction: A Porcine Study

Introduction: In 2019, 17.9 million people died from cardiovascular disease, 85% of which were due to acute myocardial infarction (AMI). Post-AMI congestive heart failure is increasing due to microvascular obstruction (MVO). MVO is the blockage of the microcirculation by atherothrombotic debris and tends to occur after coronary stenting for AMI. Current therapeutic strategies for MVO are not consistently effective. Aim: Our goal is to develop ultrasound (US)-targeted microbubble cavitation (UTMC) as a potential treatment for MVO. Methods: Initially, we demonstrated the efficacy of UTMC in a rat hindlimb model of MVO. Given these promising findings, in the current work, we expanded our investigation to a clinically relevant porcine model of myocardial MVO. On day 1, MVO was created in the left anterior descending (LAD) microcirculation and confirmed by myocardial contrast echocardiography (MCE). The MVO in the LAD bed was then treated with UTMC therapy during concurrent infusion of Definity ® contrast agent. The therapeutic ultrasound (1.3 MHz center frequency, 1.3 MPa peak negative pressure, 1 ms pulse duration) was delivered with Philips EpiQ (with S5-1 probe). Cardiac MRI was obtained at 36 hours to measure infarct size and area of MVO. At 48 hours post UTMC therapy, MCE was repeated, and the animals were euthanized. Hearts were stained with Evans Blue/ TTC dyes and sectioned for analysis of infarct size. A total of 11 pigs, 5 Control (MVO, no treatment) and 6 UTMC (MVO, UTMC treatment) were done. Results: LAD angiographic flow was improved at 48 hours post UTMC treatment in comparison to control. MCE imaging revealed that the UTMC treatment significantly improved LV systolic performance, and LAD blood volume (Figure 1), as compared to control. MRI clips showed that UTMC ameliorated MVO and left ventricular (LV) segmental wall motion and ejection fraction (EF) also improved after UTMC treatment versus control. Infarct size was reduced as shown by both Evans Blue/TTC staining and MRI. Conclusions: Taken together, we demonstrated that UTMC significantly reduced infarct size, enhanced LAD microvascular perfusion and improved LV systolic performance, and should enable clinical translation of this promising therapy.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4146203
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4146203: Ultrasound-Targeted Microbubble Cavitation For The Treatment Of Myocardial Microvascular Obstruction: A Porcine Study

John Pacella, Muhammad Wahab Amjad, Xucai Chen, Flordeliza S. Villanueva et al.
Circulation
Ultrasound and Hyperthermia Applications
article

Abstract 4146203: Ultrasound-Targeted Microbubble Cavitation For The Treatment Of Myocardial Microvascular Obstruction: A Porcine Study

John Pacella, Muhammad Wahab Amjad, Xucai Chen, Flordeliza S. Villanueva, Soheb Anwar Mohammed
article en

Abstract

Introduction: In 2019, 17.9 million people died from cardiovascular disease, 85% of which were due to acute myocardial infarction (AMI). Post-AMI congestive heart failure is increasing due to microvascular obstruction (MVO). MVO is the blockage of the microcirculation by atherothrombotic debris and tends to occur after coronary stenting for AMI. Current therapeutic strategies for MVO are not consistently effective. Aim: Our goal is to develop ultrasound (US)-targeted microbubble cavitation (UTMC) as a potential treatment for MVO. Methods: Initially, we demonstrated the efficacy of UTMC in a rat hindlimb model of MVO. Given these promising findings, in the current work, we expanded our investigation to a clinically relevant porcine model of myocardial MVO. On day 1, MVO was created in the left anterior descending (LAD) microcirculation and confirmed by myocardial contrast echocardiography (MCE). The MVO in the LAD bed was then treated with UTMC therapy during concurrent infusion of Definity ® contrast agent. The therapeutic ultrasound (1.3 MHz center frequency, 1.3 MPa peak negative pressure, 1 ms pulse duration) was delivered with Philips EpiQ (with S5-1 probe). Cardiac MRI was obtained at 36 hours to measure infarct size and area of MVO. At 48 hours post UTMC therapy, MCE was repeated, and the animals were euthanized. Hearts were stained with Evans Blue/ TTC dyes and sectioned for analysis of infarct size. A total of 11 pigs, 5 Control (MVO, no treatment) and 6 UTMC (MVO, UTMC treatment) were done. Results: LAD angiographic flow was improved at 48 hours post UTMC treatment in comparison to control. MCE imaging revealed that the UTMC treatment significantly improved LV systolic performance, and LAD blood volume (Figure 1), as compared to control. MRI clips showed that UTMC ameliorated MVO and left ventricular (LV) segmental wall motion and ejection fraction (EF) also improved after UTMC treatment versus control. Infarct size was reduced as shown by both Evans Blue/TTC staining and MRI. Conclusions: Taken together, we demonstrated that UTMC significantly reduced infarct size, enhanced LAD microvascular perfusion and improved LV systolic performance, and should enable clinical translation of this promising therapy.

CirculationVol. 150(Suppl_1)
University of Pittsburgh (US)
Good health and well-being
Openalex Percentile: Top 81%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.