Abstract 4146441: Non-invasive Algorithmic Hemodynamic Measurements Using Wearable Cloth-based Nanotechnology: Alternative to Invasive Right Heart Catheterization

Background: SimpleSense (Nanowear, New York, NY) is an FDA-cleared artificial intelligence (AI) based wearable diagnostic platform with multiparametric monitoring including 2-leads of ECG, thoracic impedance, heart sounds, blood pressure, posture and activity (Fig. 1 A). We explored the correlation between SimpleSense-derived and invasive hemodynamics (HD) parameters during right heart catheterization (RHC). The SimpleSense parameters assessed included amplitudes and width of heart sounds S1 and S2, ECG amplitudes, R to S1 and S2 times (Fig. 1 B), and pulse ejection period (PEP). PEP is a surrogate measurement that combines the pre-ejection period and left ventricular ejection time (Fig. 1 C). Methods: A single-center prospective feasibility study was conducted after IRB approval. Adult patients >18 yrs undergoing RHC were screened and enrolled after informed consent (NCT05629533). SimpleSense recorded data on the patients throughout the RHC procedure. We performed an exploratory analysis to identify potential correlations between the SimpleSense data and HD parameters utilizing maching learning. Results: Data from 11 subjects (8 Males, age:64.3 ± 10.23 yrs.) included 39 thermodilution cardiac outputs (CO) and 11 pulmonary artery pressures (PAP). The mean ± SD values of CO, cardiac index (CI), Systolic PAP, Diastolic PAP, and mean PAP were 4.4±1.9 l/min, 2.19±0.96 L/min/m 2 , 37.27±17.32 mmHg, 12.09±5.03 mmHg, and 22.72±8.42 mmHg respectively. Multiple SimpleSense derived data show statistically significant correlations with HD parameters (Fig. 2). The PEP metric exhibited the highest correlation with mean PAP and systolic PAP. Conclusion: The results highlight SimpleSense’s potential as a non-invasive AI tool that could revolutionize management by offering a reliable alternative to traditional invasive RHC. With further validation, SimpleSense may provide continuous, real-time hemodynamic information, significantly enhancing patient care and outcomes.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4146441
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4146441: Non-invasive Algorithmic Hemodynamic Measurements Using Wearable Cloth-based Nanotechnology: Alternative to Invasive Right Heart Catheterization

Arjun Kanwal, Alan Gass, Vasiliki Gregory, Ameesh Isath et al.
Circulation
Hemodynamic Monitoring and Therapy
article

Abstract 4146441: Non-invasive Algorithmic Hemodynamic Measurements Using Wearable Cloth-based Nanotechnology: Alternative to Invasive Right Heart Catheterization

Arjun Kanwal, Alan Gass, Vasiliki Gregory, Ameesh Isath, Venk Varadan, Vijay K. Varadan, Prashanth S. Kumar, Mouli Ramasamy, Shazli Khan, John M. Zimmerman
article en

Abstract

Background: SimpleSense (Nanowear, New York, NY) is an FDA-cleared artificial intelligence (AI) based wearable diagnostic platform with multiparametric monitoring including 2-leads of ECG, thoracic impedance, heart sounds, blood pressure, posture and activity (Fig. 1 A). We explored the correlation between SimpleSense-derived and invasive hemodynamics (HD) parameters during right heart catheterization (RHC). The SimpleSense parameters assessed included amplitudes and width of heart sounds S1 and S2, ECG amplitudes, R to S1 and S2 times (Fig. 1 B), and pulse ejection period (PEP). PEP is a surrogate measurement that combines the pre-ejection period and left ventricular ejection time (Fig. 1 C). Methods: A single-center prospective feasibility study was conducted after IRB approval. Adult patients >18 yrs undergoing RHC were screened and enrolled after informed consent (NCT05629533). SimpleSense recorded data on the patients throughout the RHC procedure. We performed an exploratory analysis to identify potential correlations between the SimpleSense data and HD parameters utilizing maching learning. Results: Data from 11 subjects (8 Males, age:64.3 ± 10.23 yrs.) included 39 thermodilution cardiac outputs (CO) and 11 pulmonary artery pressures (PAP). The mean ± SD values of CO, cardiac index (CI), Systolic PAP, Diastolic PAP, and mean PAP were 4.4±1.9 l/min, 2.19±0.96 L/min/m 2 , 37.27±17.32 mmHg, 12.09±5.03 mmHg, and 22.72±8.42 mmHg respectively. Multiple SimpleSense derived data show statistically significant correlations with HD parameters (Fig. 2). The PEP metric exhibited the highest correlation with mean PAP and systolic PAP. Conclusion: The results highlight SimpleSense’s potential as a non-invasive AI tool that could revolutionize management by offering a reliable alternative to traditional invasive RHC. With further validation, SimpleSense may provide continuous, real-time hemodynamic information, significantly enhancing patient care and outcomes.

CirculationVol. 150(Suppl_1)
Westchester Medical Center (US)
Openalex Percentile: Top 61%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.