Abstract 4147152: First Implantation of Atrial Leadless Pacemaker in Atriopulmonary Fontan

Introduction: Patients with Fontan circulation are at an increased risk of sinus node dysfunction and atrial tachyarrhythmias. These are associated with significant morbidity and mortality, and management constitutes a significant clinical challenge. Case Description: A 44-year-old male with right ventricular hypoplasia, tricuspid and pulmonic valve atresia and a ventricular septal defect, corrected with a modified Blalock-Taussig Shunt, bidirectional Glenn Shunt and atrio-pulmonary Fontan, was admitted with a supraventricular tachycardia (SVT) and heart failure. His electrocardiogram showed a narrow complex mid-RP tachycardia consistent with atypical atrial flutter or atrial tachycardia. His echocardiogram showed an LVEF of 21%. He was started on a beta-blocker and loaded with dofetilide, resulting in bradycardia, QT interval prolongation and Torsades de Pointes. Amiodarone was substituted, but he had incessant SVTs. He was taken for an electrophysiology study and radiofrequency ablation of a right-sided re-entrant flutter around an area of block in the anterior septum. Four additional unstable atrial tachycardias were induced but not ablated. He was discharged, then readmitted within hours for SVT. Due to insurance status, the patient was not a candidate for transplant or Fontan revision. To enable treatment with a beta-blocker, an Abbott leadless atrial pacemaker (AVEIR AR) was implanted in the high lateral Fontan, in an area of normal voltage (Figure 1). Post-implant interrogation showed stable device parameters (capture 0.25 V @ 0.4 ms, sensing 7.6 mV, impedance: 380 Ω). Conclusions: This is the first case of an AVEIR AR implanted within an atrio-pulmonary Fontan circulation. Access to atriopulmonary Fontan circulation for endovascular device therapy is feasible, but requires careful pre-procedural planning to ensure vascular patency, and anatomic and physiologic feasibility. Leadless pacing mitigates complications from endocardial and epicardial pacing systems, but long-term safety and efficacy are unknown.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4147152
Citations
1
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4147152: First Implantation of Atrial Leadless Pacemaker in Atriopulmonary Fontan

Amit Khera, Mason Marcus, Akash Kataruka, James Daniels et al.
1 citations
Circulation
Congenital Heart Disease Studies
0.39
article

Abstract 4147152: First Implantation of Atrial Leadless Pacemaker in Atriopulmonary Fontan

Amit Khera, Mason Marcus, Akash Kataruka, James Daniels, Jameson Wilbur, Patrick J. O’Hara, Emmanuella Egbonim
article en
1 citations

Abstract

Introduction: Patients with Fontan circulation are at an increased risk of sinus node dysfunction and atrial tachyarrhythmias. These are associated with significant morbidity and mortality, and management constitutes a significant clinical challenge. Case Description: A 44-year-old male with right ventricular hypoplasia, tricuspid and pulmonic valve atresia and a ventricular septal defect, corrected with a modified Blalock-Taussig Shunt, bidirectional Glenn Shunt and atrio-pulmonary Fontan, was admitted with a supraventricular tachycardia (SVT) and heart failure. His electrocardiogram showed a narrow complex mid-RP tachycardia consistent with atypical atrial flutter or atrial tachycardia. His echocardiogram showed an LVEF of 21%. He was started on a beta-blocker and loaded with dofetilide, resulting in bradycardia, QT interval prolongation and Torsades de Pointes. Amiodarone was substituted, but he had incessant SVTs. He was taken for an electrophysiology study and radiofrequency ablation of a right-sided re-entrant flutter around an area of block in the anterior septum. Four additional unstable atrial tachycardias were induced but not ablated. He was discharged, then readmitted within hours for SVT. Due to insurance status, the patient was not a candidate for transplant or Fontan revision. To enable treatment with a beta-blocker, an Abbott leadless atrial pacemaker (AVEIR AR) was implanted in the high lateral Fontan, in an area of normal voltage (Figure 1). Post-implant interrogation showed stable device parameters (capture 0.25 V @ 0.4 ms, sensing 7.6 mV, impedance: 380 Ω). Conclusions: This is the first case of an AVEIR AR implanted within an atrio-pulmonary Fontan circulation. Access to atriopulmonary Fontan circulation for endovascular device therapy is feasible, but requires careful pre-procedural planning to ensure vascular patency, and anatomic and physiologic feasibility. Leadless pacing mitigates complications from endocardial and epicardial pacing systems, but long-term safety and efficacy are unknown.

CirculationVol. 150(Suppl_1)
Southwestern Medical Center (US), The University of Texas Southwestern Medical Center (US)
Good health and well-being
Openalex Percentile: Top 32%
Congenital Heart Disease Studies
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.