Abstract 4146883: Analysis of Near-Infrared Spectroscopy Vascular Occlusion Test as a Complement to Ankle-Brachial Index and 6-Minute Walk Test in Patients Diagnosed with Peripheral Artery Disease

Introduction: Peripheral arterial disease (PAD) is caused by a lack of blood flow to the musculature relative to its metabolism which results in pain. PAD impacts up to 20% of patients around the world. PAD involves macrovascular and microvascular dysfunction. Near-infrared spectroscopy (NIRS) measures muscle oxygenation levels and assesses microvascular function. The standard of care for diagnosing PAD is the ankle-brachial index (ABI), which assesses macrovascular disease, and the 6-minute walk test (6MWT), which measures gait speed and claudication. NIRS has the potential to monitor progression of PAD. Hypothesis: NIRS measurement of muscle oxygenation, during a standard test of vascular occlusion and post-occlusive hyperemia, the vascular occlusion test (VOT), is predictive of PAD severity as determined by ABI and 6MWT. Methods: We studied 24 patients diagnosed with PAD. The mean age of the patients was 71.3 years, including 54% (n=13) males and 46% (n=11) females. The VOT consisted of rest, occlusion, and reperfusion phases each lasting 5 min (15 min total). Muscle oxygen saturation levels were recorded at 2 hertz. For every patient, 6 features were extracted from the VOT data using computational methods. The VOT features from 15 patients were used to train function-fitting neural network models to predict ABI and 6MWT Continuous Distance. The models were then used to predict ABI and 6MWT Continuous Distance from the VOT features of 9 test patients not used in the training, Results: For patients in the test set, the ABI and 6MWT Continuous Distance predicted by the models differed from the actual measurements by 14%±13% and 15%±17%, respectively (Figure 1). For patients in the training set, the ABI and 6MWT Continuous Distance predicted by the models differed from the actual measurements by 0±0% and 12%±11%, respectively (Figure 1). Conclusion: The VOT has the potential to predict the ABI and 6MWT Continuous Distance of patients diagnosed with PAD, suggesting that the VOT can be automated and used to monitor the severity of PAD. With more data from both healthy patients and PAD patients, and improvement of the model, we anticipate that the VOT will complement ABI and 6MWT in the diagnosis and monitoring of PAD.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4146883
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4146883: Analysis of Near-Infrared Spectroscopy Vascular Occlusion Test as a Complement to Ankle-Brachial Index and 6-Minute Walk Test in Patients Diagnosed with Peripheral Artery Disease

Judy Delp, Cesar Rodriguez, Santh Prakash Lanka, Joshua J. Maraj et al.
Circulation
Peripheral Artery Disease Management
article

Abstract 4146883: Analysis of Near-Infrared Spectroscopy Vascular Occlusion Test as a Complement to Ankle-Brachial Index and 6-Minute Walk Test in Patients Diagnosed with Peripheral Artery Disease

Judy Delp, Cesar Rodriguez, Santh Prakash Lanka, Joshua J. Maraj, Carl J. Ade, Yaman Alsabbagh, Xiuwen Liu, Sam Farres
article en

Abstract

Introduction: Peripheral arterial disease (PAD) is caused by a lack of blood flow to the musculature relative to its metabolism which results in pain. PAD impacts up to 20% of patients around the world. PAD involves macrovascular and microvascular dysfunction. Near-infrared spectroscopy (NIRS) measures muscle oxygenation levels and assesses microvascular function. The standard of care for diagnosing PAD is the ankle-brachial index (ABI), which assesses macrovascular disease, and the 6-minute walk test (6MWT), which measures gait speed and claudication. NIRS has the potential to monitor progression of PAD. Hypothesis: NIRS measurement of muscle oxygenation, during a standard test of vascular occlusion and post-occlusive hyperemia, the vascular occlusion test (VOT), is predictive of PAD severity as determined by ABI and 6MWT. Methods: We studied 24 patients diagnosed with PAD. The mean age of the patients was 71.3 years, including 54% (n=13) males and 46% (n=11) females. The VOT consisted of rest, occlusion, and reperfusion phases each lasting 5 min (15 min total). Muscle oxygen saturation levels were recorded at 2 hertz. For every patient, 6 features were extracted from the VOT data using computational methods. The VOT features from 15 patients were used to train function-fitting neural network models to predict ABI and 6MWT Continuous Distance. The models were then used to predict ABI and 6MWT Continuous Distance from the VOT features of 9 test patients not used in the training, Results: For patients in the test set, the ABI and 6MWT Continuous Distance predicted by the models differed from the actual measurements by 14%±13% and 15%±17%, respectively (Figure 1). For patients in the training set, the ABI and 6MWT Continuous Distance predicted by the models differed from the actual measurements by 0±0% and 12%±11%, respectively (Figure 1). Conclusion: The VOT has the potential to predict the ABI and 6MWT Continuous Distance of patients diagnosed with PAD, suggesting that the VOT can be automated and used to monitor the severity of PAD. With more data from both healthy patients and PAD patients, and improvement of the model, we anticipate that the VOT will complement ABI and 6MWT in the diagnosis and monitoring of PAD.

CirculationVol. 150(Suppl_1)
Florida State University (US), Kansas State University (US), University of Tennessee System (US), Jacksonville College (US), WinnMed (US), Mayo Clinic in Florida (US), University of Tennessee at Knoxville (US)
Good health and well-being
Openalex Percentile: Top 61%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.