Abstract 4147462: Ambulatory Breath Analyzer for Measuring Cardiac Output

Background: Knowing heart failure patients’ cardiac output at outpatient setting can guide optimization of medical therapy and detect decompensation early to trigger timely response; therefore, following patients’ cardiac output has potential to greatly improve care of heart failure patients. Unfortunately, an easy to use ambulatory device that can measure cardiac output at patients’ homes currently does not exist. Hypothesis: One can derive cardiac output by measuring carbon dioxide (CO 2 ) and flow of exhaled breath because right heart delivers CO 2 laden blood to the lungs, right heart = left heart in blood flow. Method: We made a novel breath analyzer that measures cardiac output from exhaled breath. This device uses [CO 2 ] and volume of exhaled breath as input. Exhaled flow rate of CO 2 is measured, then divided by the difference between venous and arterial [CO 2 ]. The difference is calculated from exhaled CO 2 input to a novel formula. We built and tested a prototype to implement this method. We designed a heated breath flow path with baffles to combat the high humidity in breath. Custom software then calculates cardiac output in real time. We used this prototype to measure the cardiac output at rest and after set pace treadmill jogging. Results: The prototype (fig) featured small dimensions, light weight, and compatibility with a typical laptop computer. Reliability testing showed a 1.85% standard deviation in volume detection over 70 test breaths. Carbon dioxide detection was compared to high-sensitivity cavity ringdown spectroscopy with an error of 1.14%. Measurement of cardiac output was performed on 11 human volunteer subjects. Echocardiogram of stroke volume X heart rate was used as reference. Cardiac output measurements from our device correlated strongly with echocardiogram reference both at rest and after exercise, giving an R=0.83 and p=3X10 -6 . Conclusions: We developed a novel method and device that measures cardiac output from exhaled breath, understanding that further validation in heart failure population is needed. This device can be used to measure cardiac output at outpatient settings to improve the quality of care for a great many patients.

Authors

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4147462
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4147462: Ambulatory Breath Analyzer for Measuring Cardiac Output

John E. Hale, Alexandre Kolomenski, Carl Tong, H. A. Schuessler
Circulation
Heart Rate Variability and Autonomic Control
article

Abstract 4147462: Ambulatory Breath Analyzer for Measuring Cardiac Output

John E. Hale, Alexandre Kolomenski, Carl Tong, H. A. Schuessler
article en

Abstract

Background: Knowing heart failure patients’ cardiac output at outpatient setting can guide optimization of medical therapy and detect decompensation early to trigger timely response; therefore, following patients’ cardiac output has potential to greatly improve care of heart failure patients. Unfortunately, an easy to use ambulatory device that can measure cardiac output at patients’ homes currently does not exist. Hypothesis: One can derive cardiac output by measuring carbon dioxide (CO 2 ) and flow of exhaled breath because right heart delivers CO 2 laden blood to the lungs, right heart = left heart in blood flow. Method: We made a novel breath analyzer that measures cardiac output from exhaled breath. This device uses [CO 2 ] and volume of exhaled breath as input. Exhaled flow rate of CO 2 is measured, then divided by the difference between venous and arterial [CO 2 ]. The difference is calculated from exhaled CO 2 input to a novel formula. We built and tested a prototype to implement this method. We designed a heated breath flow path with baffles to combat the high humidity in breath. Custom software then calculates cardiac output in real time. We used this prototype to measure the cardiac output at rest and after set pace treadmill jogging. Results: The prototype (fig) featured small dimensions, light weight, and compatibility with a typical laptop computer. Reliability testing showed a 1.85% standard deviation in volume detection over 70 test breaths. Carbon dioxide detection was compared to high-sensitivity cavity ringdown spectroscopy with an error of 1.14%. Measurement of cardiac output was performed on 11 human volunteer subjects. Echocardiogram of stroke volume X heart rate was used as reference. Cardiac output measurements from our device correlated strongly with echocardiogram reference both at rest and after exercise, giving an R=0.83 and p=3X10 -6 . Conclusions: We developed a novel method and device that measures cardiac output from exhaled breath, understanding that further validation in heart failure population is needed. This device can be used to measure cardiac output at outpatient settings to improve the quality of care for a great many patients.

CirculationVol. 150(Suppl_1)
Openalex Percentile: Top 62%
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.