Abstract 4146902: Invasive versus Echocardiographic Hemodynamics in Two Genetically Modified Porcine to Human Cardiac Xenotransplants

Background: Our institution performed two transgenic porcine to human cardiac xenotransplantations. There is limited data with the first cardiac xenograft suggesting echocardiographic assessment of the cardiac xenograft in humans correlates with invasive hemodynamic assessments. We investigated whether echocardiographic-derived hemodynamic indices would correlate with invasive measurements in both cardiac xenotransplants. Methods: Serial transthoracic echocardiography (TTE) and right heart catheterizations (RHC) were performed in the cardiac xenografts. Retrospective analysis of TTE and invasive hemodynamics were analyzed in both the first and second xenotransplant to assess correlation between various parameters. Invasive hemodynamic measures include right atrial pressure (RAP), pulmonary artery systolic and diastolic pressures (PASP, PADP), Fick cardiac output (CO), cardiac index (CI), right ventricular stroke work index (RVSWI), and cardiac power output (CPO). TTE measurements and calculations included: RAP, PASP calculated via tricuspid regurgitation velocity (TRV), PADP based on end diastolic pressure gradient, tricuspid annular plane systolic excursion (TAPSE), right ventricular outflow time-velocity integral (TVI RVOT), pulmonary vascular resistance (PVR) = [TRV/TVI RVOT x 10 + 0.16], CO, CI, CPO = [mean arterial pressure echo-derived CO / 451], and right ventricular stroke work index (RVCPI) = [4x(TRV)^2) x TAPSE], as a surrogate of RVSWI. Results: Pearson correlation using invasive measurements at the time of TTE for cardiac output showed a positive correlation of 0.69 (p = 0.06) with a trend towards significance. Pearson correlation of RVSWI and RVCPI demonstrated a significant positive correlation of 0.83 (p = 0.04). Conclusions: In the first two cardiac xenotransplants, there remains a positive correlation in hemodynamic markers between invasive and noninvasive measurements. Given the intense interest in cardiac xenotransplant, continued investigation in correlating noninvasive and invasive hemodynamic markers will provide real-time prognostic and clinical value for future research.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4146902
Primary Topic
Xenotransplantation and immune response
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4146902: Invasive versus Echocardiographic Hemodynamics in Two Genetically Modified Porcine to Human Cardiac Xenotransplants

Manjula Ananthram, Andrew Tully, Cullen Soares, Sadegh Asadi et al.
Circulation
Xenotransplantation and immune response
article

Abstract 4146902: Invasive versus Echocardiographic Hemodynamics in Two Genetically Modified Porcine to Human Cardiac Xenotransplants

Manjula Ananthram, Andrew Tully, Cullen Soares, Sadegh Asadi, Timm Dickfeld, Alison Grazioli, Muhammad Mohiuddin, Bartley P. Griffith, Alice Tang, Allison S. Lankford, Anuj Gupta, Javier Galindo, Brian Barr, Susie Hong-Zohlman, Erika Feller
article en

Abstract

Background: Our institution performed two transgenic porcine to human cardiac xenotransplantations. There is limited data with the first cardiac xenograft suggesting echocardiographic assessment of the cardiac xenograft in humans correlates with invasive hemodynamic assessments. We investigated whether echocardiographic-derived hemodynamic indices would correlate with invasive measurements in both cardiac xenotransplants. Methods: Serial transthoracic echocardiography (TTE) and right heart catheterizations (RHC) were performed in the cardiac xenografts. Retrospective analysis of TTE and invasive hemodynamics were analyzed in both the first and second xenotransplant to assess correlation between various parameters. Invasive hemodynamic measures include right atrial pressure (RAP), pulmonary artery systolic and diastolic pressures (PASP, PADP), Fick cardiac output (CO), cardiac index (CI), right ventricular stroke work index (RVSWI), and cardiac power output (CPO). TTE measurements and calculations included: RAP, PASP calculated via tricuspid regurgitation velocity (TRV), PADP based on end diastolic pressure gradient, tricuspid annular plane systolic excursion (TAPSE), right ventricular outflow time-velocity integral (TVI RVOT), pulmonary vascular resistance (PVR) = [TRV/TVI RVOT x 10 + 0.16], CO, CI, CPO = [mean arterial pressure echo-derived CO / 451], and right ventricular stroke work index (RVCPI) = [4x(TRV)^2) x TAPSE], as a surrogate of RVSWI. Results: Pearson correlation using invasive measurements at the time of TTE for cardiac output showed a positive correlation of 0.69 (p = 0.06) with a trend towards significance. Pearson correlation of RVSWI and RVCPI demonstrated a significant positive correlation of 0.83 (p = 0.04). Conclusions: In the first two cardiac xenotransplants, there remains a positive correlation in hemodynamic markers between invasive and noninvasive measurements. Given the intense interest in cardiac xenotransplant, continued investigation in correlating noninvasive and invasive hemodynamic markers will provide real-time prognostic and clinical value for future research.

CirculationVol. 150(Suppl_1)
University of Maryland, Baltimore (US), MedStar Union Memorial Hospital (US)
Openalex Percentile: Top 61%
Xenotransplantation and immune response
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.