Abstract Sa405: Unlocking the Potential of Mechanical CPR: The Role of Real-Time Feedback Before Device Application

Background: Current AHA guidelines do not recommend routine use of Mechanical CPR devices due to the decline in CPR quality during their preparation and application. However, Manual chest compressions during transport can reduce CPR quality. In situations where maintaining high-quality CPR is challenging, Mechanical CPR devices are essential. We hypothesized that real-time feedback (RF) could help maintain the quality of Manual CPR before Mechanical CPR devices are activated. Objectives: To investigate the impact of RF on the quality of Manual CPR before the activation of Mechanical CPR devices. Methods: This retrospective observational study included OHCA cases where Mechanical CPR using the LUCAS 3® device was performed between May 2023 and February 2024. We compared chest compression quality parameters, including Depth Achievement Rate (≥5cm) (%), Depth (cm), Rate Achievement Rate (100-120/min) (%), Rate (/min), Longest Interruption (s), and Chest Compression Fraction (CCF) (%) during Manual chest compressions before the application of the Mechanical CPR device between two periods, using the ZOLL X Series® monitor. During the first 5 months, RF was not used, and EMS teams could not see RF data, but chest compression quality parameters were recorded. During the subsequent 5 months, RF was displayed, and the same parameters were recorded. Results: The results are summarized in the attached figure. There were 10 cases without RF and 37 with RF. The RF group showed significant improvements in depth achievement rate (≥5cm) and compression depth. The rate achievement rate (100-120/min) and compression rate were similar between groups. The longest interruption time was shorter in the RF group, and the CCF was higher, although these differences were not statistically significant. The median duration of Manual CPR before applying the Mechanical CPR device was longer in the RF group [382s, IQR 110-654] compared to the non-RF group [156s, IQR 67-283], p=0.065. Conclusions: RF significantly improved the depth achievement rate and compression depth during Manual CPR before applying Mechanical CPR devices. Trends towards shorter interruption times and higher CCF in the RF group suggest RF may help maintain CPR quality. However, the retrospective nature and limited sample size may affect the generalizability of the results.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.sa405
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract Sa405: Unlocking the Potential of Mechanical CPR: The Role of Real-Time Feedback Before Device Application

Yoshihiro Hagiwara, Kensuke Fujita, Takayuki Ogura, Eri Douno et al.
Circulation
Cardiac Arrest and Resuscitation
article

Abstract Sa405: Unlocking the Potential of Mechanical CPR: The Role of Real-Time Feedback Before Device Application

Yoshihiro Hagiwara, Kensuke Fujita, Takayuki Ogura, Eri Douno, Mitsuyuki Miyazato
article en

Abstract

Background: Current AHA guidelines do not recommend routine use of Mechanical CPR devices due to the decline in CPR quality during their preparation and application. However, Manual chest compressions during transport can reduce CPR quality. In situations where maintaining high-quality CPR is challenging, Mechanical CPR devices are essential. We hypothesized that real-time feedback (RF) could help maintain the quality of Manual CPR before Mechanical CPR devices are activated. Objectives: To investigate the impact of RF on the quality of Manual CPR before the activation of Mechanical CPR devices. Methods: This retrospective observational study included OHCA cases where Mechanical CPR using the LUCAS 3® device was performed between May 2023 and February 2024. We compared chest compression quality parameters, including Depth Achievement Rate (≥5cm) (%), Depth (cm), Rate Achievement Rate (100-120/min) (%), Rate (/min), Longest Interruption (s), and Chest Compression Fraction (CCF) (%) during Manual chest compressions before the application of the Mechanical CPR device between two periods, using the ZOLL X Series® monitor. During the first 5 months, RF was not used, and EMS teams could not see RF data, but chest compression quality parameters were recorded. During the subsequent 5 months, RF was displayed, and the same parameters were recorded. Results: The results are summarized in the attached figure. There were 10 cases without RF and 37 with RF. The RF group showed significant improvements in depth achievement rate (≥5cm) and compression depth. The rate achievement rate (100-120/min) and compression rate were similar between groups. The longest interruption time was shorter in the RF group, and the CCF was higher, although these differences were not statistically significant. The median duration of Manual CPR before applying the Mechanical CPR device was longer in the RF group [382s, IQR 110-654] compared to the non-RF group [156s, IQR 67-283], p=0.065. Conclusions: RF significantly improved the depth achievement rate and compression depth during Manual CPR before applying Mechanical CPR devices. Trends towards shorter interruption times and higher CCF in the RF group suggest RF may help maintain CPR quality. However, the retrospective nature and limited sample size may affect the generalizability of the results.

CirculationVol. 150(Suppl_1)
Saiseikai Utsunomiya hospital (JP)
Quality Education
Openalex Percentile: Top 64%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.