Abstract 4147752: Agreement of Doppler Flow Velocity Reserve With PET Flow Reserve in Angina Without Obstructive Coronaries
Background: Angina with no obstructive coronary arteries (ANOCA) is clinically challenging to diagnose and manage. The agreement between Doppler-derived coronary flow reserve (CFR Doppl ) and PET-derived CFR (CFR PET ) in patients with ANOCA remains unclear. Aims: To evaluate the correlation between Doppler- and PET-derived CFR in patients with ANOCA. Methods: We conducted a single-center, retrospective study of adult patients (age ≥18 years) with ANOCA who were referred for evaluation of possible microvascular ischemia with Doppler- and PET-derived CFR at the Mayo Clinic (Rochester, MN) between January 1, 2018, and May 1, 2024. Pearson correlation was used to quantify the association between Doppler- and PET-derived CFR. Agreement between Doppler- and PET-derived CFR was assessed by Bland-Altman analysis using a 2-way mixed effects model with measures of absolute agreement. Results: A total of 66 patients were initially identified, of which 40 were included in the final analysis (66.7% female, median age 58 years [Q1-Q3: 45-66 years]). Median time between PET- and Doppler-derived CFR was 8 days (Q1-Q3: 1-31 days). Median CFR Doppl was 2.75 (IQR: 2.23-3.28) and median CFR PET was 2.50 (IQR: 2.10-3.10). Doppler-derived CFR displayed a wider range than PET-derived CFR (0.8-5.2 vs 1.2-4.0). A strong correlation was found between Doppler- and PET-derived CFR ( r= 0.81; p<0.001). The corresponding Bland-Altman plot showed an overall bias of 0.27±0.56 (intraclass coefficient=0.85; p<0.001). Conclusions: While invasive coronary angiography with CFR Doppl is the gold-standard for the diagnostic evaluation of ANOCA, PET imaging with CFR PET offers an excellent first line non-invasive modality for diagnosis of coronary microvascular dysfunction.
Authors
- Mahmoud Ismayl (ORCID: https://orcid.org/0000-0001-9033-7835)
- Panithaya Chareonthaitawee (ORCID: https://orcid.org/0000-0002-3811-8712)
- John P. Bois (ORCID: https://orcid.org/0000-0003-4972-5160)
- Abhiram Prasad (ORCID: https://orcid.org/0000-0001-9252-5602)
- Claire E. Raphael (ORCID: https://orcid.org/0000-0002-2206-0413)
Institutions
- Mayo Clinic (US)
Publication Details
- Journal
- Circulation
- Published
- 2024-11-12
- DOI
- https://doi.org/10.1161/circ.150.suppl_1.4147752
- Citations
- 1
- Primary Topic
- Cardiac Imaging and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.40