Electric Diagram for the Study of Series Electric Arcs Fault

Electric arc faults in series with the load in a single-phase alternating current circuit are difficult to detect due to the decrease in the effective value of the current when they occur. At the same time, they are extremely dangerous because of the possibility of producing fires caused by an electrical fault. Electric arc detection devices are the only electrical protection devices able to detect and interrupt the supply of circuits when this type of fault occurs. To study the operation of these protective devices, a laboratory electric diagram is proposed, through which two types of electric arc faults are simulated. The electrical parameters measured are the discharge voltage, the electric current through the arc and the derivative of the noise produced by the electric arc.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/icate62934.2024.10748609
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.21
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electric Diagram for the Study of Series Electric Arcs Fault

Sorin Sintea, Bogdan Hnatiuc, Mihaela Hnatiuc
1 citations
Electrical Fault Detection and Protection
0.21
article

Electric Diagram for the Study of Series Electric Arcs Fault

Sorin Sintea, Bogdan Hnatiuc, Mihaela Hnatiuc
article en
1 citations

Abstract

Electric arc faults in series with the load in a single-phase alternating current circuit are difficult to detect due to the decrease in the effective value of the current when they occur. At the same time, they are extremely dangerous because of the possibility of producing fires caused by an electrical fault. Electric arc detection devices are the only electrical protection devices able to detect and interrupt the supply of circuits when this type of fault occurs. To study the operation of these protective devices, a laboratory electric diagram is proposed, through which two types of electric arc faults are simulated. The electrical parameters measured are the discharge voltage, the electric current through the arc and the derivative of the noise produced by the electric arc.

Constanta Maritime University (RO)
Climate action
Openalex Percentile: Top 46%
Electrical Fault Detection and Protection
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Electric Diagram for the Study of Series Electric Arcs Fault — Sorin Sintea, Bogdan Hnatiuc, et al. · (2024) | TGRS Research Map | TGRS