A Low-Cost Microwave Hybrid Biosensor for Glucose Concentration Sensing

This study uses a hybrid biosensor consisting of a patch antenna with a defected ground plane and a frequency-selective surface (FSS) to detect glucose concentration in the microwave frequency region. The sensing mechanism is based on identifying the relative permittivity and loss tangent variations caused by different ratios of glucose-distilled water solutions placed in the area of the sample under test (SUT). This study tested four glucose-distilled water solutions in the SUT region: 72 mg/dL, 216 mg/dL, 330 mg/dL, and 600 mg/dL. The Debye model is utilized to ascertain the dielectric characteristics of the solutions. When the volume percentage of glucose in the glucose-deionized water solutions in the SUT increased from 72 mg/dL to 600 mg/dL, a frequency shift of 44 MHz was observed in the resonance frequency of the hybrid sensor called Sensor 1. To show the effect of mutual coupling between the defected ground plane and the FSS on sensitivity parameters in the hybrid sensor structure, a new sensor called Sensor 2 was designed. Sensor 2 has the same geometry and dimensional parameters as Sensor 1 but only consists of a patch antenna with a defected ground plane. A frequency shift of 7 MHz was noted in the resonance frequency of Sensor 2 when the volume percentage of glucose in the glucose-deionized water solutions in the SUT increased from 72 mg/dL to 600 mg/dL. According to the simulation results, the sensitivity of Sensor 1 was calculated as 83.333 kHz/mg dL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, while Sensor 2 was 13.258 kHz/mg dL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>. Thus, it is shown that FSS can be used in antenna-based sensor structures for sensitivity improvement.

Authors

Institutions

Publication Details

Published
2024-10-24
DOI
https://doi.org/10.1109/icate62934.2024.10748696
Citations
1
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Low-Cost Microwave Hybrid Biosensor for Glucose Concentration Sensing

Mesut Kartal, Umut Köse
1 citations
Microwave and Dielectric Measurement Techniques
0.21
article

A Low-Cost Microwave Hybrid Biosensor for Glucose Concentration Sensing

Mesut Kartal, Umut Köse
article en
1 citations

Abstract

This study uses a hybrid biosensor consisting of a patch antenna with a defected ground plane and a frequency-selective surface (FSS) to detect glucose concentration in the microwave frequency region. The sensing mechanism is based on identifying the relative permittivity and loss tangent variations caused by different ratios of glucose-distilled water solutions placed in the area of the sample under test (SUT). This study tested four glucose-distilled water solutions in the SUT region: 72 mg/dL, 216 mg/dL, 330 mg/dL, and 600 mg/dL. The Debye model is utilized to ascertain the dielectric characteristics of the solutions. When the volume percentage of glucose in the glucose-deionized water solutions in the SUT increased from 72 mg/dL to 600 mg/dL, a frequency shift of 44 MHz was observed in the resonance frequency of the hybrid sensor called Sensor 1. To show the effect of mutual coupling between the defected ground plane and the FSS on sensitivity parameters in the hybrid sensor structure, a new sensor called Sensor 2 was designed. Sensor 2 has the same geometry and dimensional parameters as Sensor 1 but only consists of a patch antenna with a defected ground plane. A frequency shift of 7 MHz was noted in the resonance frequency of Sensor 2 when the volume percentage of glucose in the glucose-deionized water solutions in the SUT increased from 72 mg/dL to 600 mg/dL. According to the simulation results, the sensitivity of Sensor 1 was calculated as 83.333 kHz/mg dL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>, while Sensor 2 was 13.258 kHz/mg dL<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup>. Thus, it is shown that FSS can be used in antenna-based sensor structures for sensitivity improvement.

Fatih Sultan Mehmet Waqf University (TR), Istanbul Technical University (TR)
Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
Affordable and clean energy
Openalex Percentile: Top 46%
Microwave and Dielectric Measurement Techniques
0.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Low-Cost Microwave Hybrid Biosensor for Glucose Concentration Sensing — Mesut Kartal, Umut Köse · (2024) | TGRS Research Map | TGRS