Can an Intramedullary Nail Be Used for Hip Fracture Prevention in a Sideways Fall Scenario?

<div>Fragility fracture of the hip is a global health concern with generally poor outcomes. Clinical studies have shown prophylactic augmentation of the femur to be a plausible intervention with success in some approaches; however, its use is not yet widespread in the clinical community. We aimed to evaluate the efficacy and clinical safety of prophylactic intramedullary nailing for hip fracture prevention after a fall impact in six cadaveric pelvis–femurs. Post-fall fracture status of the native specimens was determined in a virtual control group built using a validated and peer-reviewed finite element method. A commercially available intramedullary nailing system was prophylactically implanted in all specimens. After augmentation, specimens were subjected to an experimental sideways fall impact and inspected for fracture. Overall, fracture status was unchanged or lowered in severity in the augmented group compared to the native control group. No sign of femur fracture was found in the group augmented by intramedullary nailing, but two augmented specimens exhibited pelvis fractures after the impact. No safety concerns associated with prophylactic nailing were found. These results suggest that prophylactic nailing may reduce the potential for hip fracture in a sideways fall impact but would not reduce the likelihood of pelvis fracture, and may shift femur fractures to instead be pelvis fractures. This study provides a robust biomechanical evaluation of prophylactic augmentation with a device already familiar to orthopedic surgeons, broadening the options currently considered for the prevention of hip fractures.</div>

Authors

Institutions

Publication Details

Journal
SAE International Journal of Transportation Safety
Published
2024-11-12
DOI
https://doi.org/10.4271/09-12-02-0013
Primary Topic
Hip and Femur Fractures
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can an Intramedullary Nail Be Used for Hip Fracture Prevention in a Sideways Fall Scenario?

Benedikt Helgason, Peter A. Cripton, Pierre Guy, Emily K. Bliven et al.
SAE International Journal of Transportation Safety
Hip and Femur Fractures
article

Can an Intramedullary Nail Be Used for Hip Fracture Prevention in a Sideways Fall Scenario?

Benedikt Helgason, Peter A. Cripton, Pierre Guy, Emily K. Bliven, Alexander Baker, Anita Fung
article en

Abstract

<div>Fragility fracture of the hip is a global health concern with generally poor outcomes. Clinical studies have shown prophylactic augmentation of the femur to be a plausible intervention with success in some approaches; however, its use is not yet widespread in the clinical community. We aimed to evaluate the efficacy and clinical safety of prophylactic intramedullary nailing for hip fracture prevention after a fall impact in six cadaveric pelvis–femurs. Post-fall fracture status of the native specimens was determined in a virtual control group built using a validated and peer-reviewed finite element method. A commercially available intramedullary nailing system was prophylactically implanted in all specimens. After augmentation, specimens were subjected to an experimental sideways fall impact and inspected for fracture. Overall, fracture status was unchanged or lowered in severity in the augmented group compared to the native control group. No sign of femur fracture was found in the group augmented by intramedullary nailing, but two augmented specimens exhibited pelvis fractures after the impact. No safety concerns associated with prophylactic nailing were found. These results suggest that prophylactic nailing may reduce the potential for hip fracture in a sideways fall impact but would not reduce the likelihood of pelvis fracture, and may shift femur fractures to instead be pelvis fractures. This study provides a robust biomechanical evaluation of prophylactic augmentation with a device already familiar to orthopedic surgeons, broadening the options currently considered for the prevention of hip fractures.</div>

SAE International Journal of Transportation SafetyVol. 12(2)
ETH Zurich (CH), Institute for Biomedical Engineering (CH)
Good health and well-being
Openalex Percentile: Top 61%
Hip and Femur Fractures
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.