Advanced FE nonlinear numerical modeling to predict historical masonry vaults failure: Assessment of risk collapse for a long span cloister vault heavily loaded at the crown by means of a general-purpose numerical protocol

• Numerical evaluation of the residual resources before collapse for historical masonry vaults. • Proposal of simple but advanced FE models directly usable in common design. • Paradigmatic case study of a vault subjected to a heavy point load located at the mid-span. • Role played by geometry and backfill in the realistic prediction of the failure loads. • Proposal of effective strengthening interventions based on FE results to prevent failure. A simple and rapid approach aimed at the failure prediction of historical masonry vaults exhibiting stability issues under gravity loads is presented and applied to a paradigmatic case study in Italy. The benchmark structure under examination is a cloister vault with a considerable span, over which a slender load-bearing wall was built over the keystone. The urgency of a stability assessment to prevent failure is evident. The geometrical characteristics and some material information are obtained through in situ surveys. To assess its stability, determine the risk of collapse and propose a sound strengthening on the already cracked structure, a general numerical protocol that comprises five different 2D finite element models is proposed, each with different assumptions. In all models, blocks are discretized using 4-noded elastic elements in plane-strain, and mortar joints are modeled employing (i) orthotropic shell elements coupled with (ii) fragile cutoff bars. Model 1 considers only the arch without spandrels, unlike Model 2, which comprises them. The backfill is included in Models 3 and 4 using a system of equivalent forces mimicking both soil self-weight and the horizontal passive pressure, whilst Model 5 −used for validation purposes- employs elastic perfectly plastic elements that obey a Mohr-Coulomb failure criterion. Model 3 and Model 4 differ only in the dimension of the buttresses, which are thickened in Model 4 to improve the stability of the vault. Additionally, in Model 3 the effect of a possible retrofitting intervention is studied, having an insight into the role played by Carbon Fiber Reinforced Polymer (CFRP) strips positioned at the intrados and modeled with elastic perfectly ductile cutoff bars connected to surface nodes, thus ensuring a perfect bond between substrate and reinforcement. After a thorough analysis of the results, which focuses on both global force–displacement curves and failure mechanisms triggered, a safety assessment of the cloister vault is provided.

Authors

Institutions

Publication Details

Journal
Engineering Failure Analysis
Published
2024-11-15
DOI
https://doi.org/10.1016/j.engfailanal.2024.109070
Citations
43
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
11.22
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced FE nonlinear numerical modeling to predict historical masonry vaults failure: Assessment of risk collapse for a long span cloister vault heavily loaded at the crown by means of a general-purpose numerical protocol

Natalia Pingaro, Gabriele Milani, Martina Buzzetti
43 citations
Engineering Failure Analysis
Masonry and Concrete Structural Analysis
11.22
article

Advanced FE nonlinear numerical modeling to predict historical masonry vaults failure: Assessment of risk collapse for a long span cloister vault heavily loaded at the crown by means of a general-purpose numerical protocol

Natalia Pingaro, Gabriele Milani, Martina Buzzetti
article en
43 citations

Abstract

• Numerical evaluation of the residual resources before collapse for historical masonry vaults. • Proposal of simple but advanced FE models directly usable in common design. • Paradigmatic case study of a vault subjected to a heavy point load located at the mid-span. • Role played by geometry and backfill in the realistic prediction of the failure loads. • Proposal of effective strengthening interventions based on FE results to prevent failure. A simple and rapid approach aimed at the failure prediction of historical masonry vaults exhibiting stability issues under gravity loads is presented and applied to a paradigmatic case study in Italy. The benchmark structure under examination is a cloister vault with a considerable span, over which a slender load-bearing wall was built over the keystone. The urgency of a stability assessment to prevent failure is evident. The geometrical characteristics and some material information are obtained through in situ surveys. To assess its stability, determine the risk of collapse and propose a sound strengthening on the already cracked structure, a general numerical protocol that comprises five different 2D finite element models is proposed, each with different assumptions. In all models, blocks are discretized using 4-noded elastic elements in plane-strain, and mortar joints are modeled employing (i) orthotropic shell elements coupled with (ii) fragile cutoff bars. Model 1 considers only the arch without spandrels, unlike Model 2, which comprises them. The backfill is included in Models 3 and 4 using a system of equivalent forces mimicking both soil self-weight and the horizontal passive pressure, whilst Model 5 −used for validation purposes- employs elastic perfectly plastic elements that obey a Mohr-Coulomb failure criterion. Model 3 and Model 4 differ only in the dimension of the buttresses, which are thickened in Model 4 to improve the stability of the vault. Additionally, in Model 3 the effect of a possible retrofitting intervention is studied, having an insight into the role played by Carbon Fiber Reinforced Polymer (CFRP) strips positioned at the intrados and modeled with elastic perfectly ductile cutoff bars connected to surface nodes, thus ensuring a perfect bond between substrate and reinforcement. After a thorough analysis of the results, which focuses on both global force–displacement curves and failure mechanisms triggered, a safety assessment of the cloister vault is provided.

Engineering Failure AnalysisVol. 167
Politecnico di Milano (IT)
Sustainable cities and communities
Openalex Percentile: Top 1%
Masonry and Concrete Structural Analysis
11.22
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.