Abstract 4140246: AI and Quantum Sensors: Realization of a Safe and Effective Unshielded Bedside Magnetocardiogram to Detect Ischemia in the Emergency Room

Introduction: Magnetocardiography (MCG) has potential to significantly improve cardiac disease diagnosis, but adoption in clinical practice is hindered by high cost and large footprints of traditional systems. Hence, we developed a bedside, non-contact MCG system that utilizes quantum magnetometers and AI methods to extract validated cardiac biomarkers, while rejecting ambient magnetic interference. Goal: To investigate the safety and efficacy of the bedside MCG device in identifying non-ST-segment elevation myocardial infarction (N-STEMI) among patients from an urban emergency department. Methods: The MCG system is a custom prototype with 26 optically pumped magnetometers - quantum sensors that measure cardiac magnetic fields with picoTesla sensitivity. We recruited a diverse sample of 78 adult patients (72 with analyzable data) presenting to the ED with chest pain symptoms suggestive of ACS who were not experiencing STEMI (mean age=56 years; 64% male; 11% Asian, 28% Black, 7% American Indian/Alaska Native, 44% White, 1% Native Hawaiian/Pacific Islander, 9% other/unknown; 6 technically unusable recordings, 8%). A 5-minute MCG was recorded within 2 hours of an initial 12-lead ECG. Signal processing and AI algorithms were used to remove ambient interference and recover cardiac signal. Literature-based MCG markers were inputted to a classification and regression tree (CART) model to classify patients as NSTEMI ACS rule-in or rule-out. Results: The CART model successfully discriminated clinically determined ACS rule-in patients (n=7) from rule-outs (n=65) with sensitivity=86% and specificity=92%. The most predictive MCG markers were the field pattern angle difference between R- and T-wave maximum, the power ratio between the R- and T-waves, and the field maximum to minimum ratio. No adverse events were reported. Conclusions: MCG is a promising, non-contact diagnostic tool for emergency physicians diagnosing suspected ACS cases. This pilot study shows that a bedside, quantum-sensing MCG that utilizes AI has the potential to provide safe and accurate diagnostic results, and it is feasible to integrate the device into the ED workflow.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4140246
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4140246: AI and Quantum Sensors: Realization of a Safe and Effective Unshielded Bedside Magnetocardiogram to Detect Ischemia in the Emergency Room

Deepak L. Bhatt, Johanna Contreras, Jeffrey Bander, Geoffrey Z. Iwata et al.
1 citations
Circulation
Non-Invasive Vital Sign Monitoring
0.18
article

Abstract 4140246: AI and Quantum Sensors: Realization of a Safe and Effective Unshielded Bedside Magnetocardiogram to Detect Ischemia in the Emergency Room

Deepak L. Bhatt, Johanna Contreras, Jeffrey Bander, Geoffrey Z. Iwata, Sajiny John, Kirstin Aschbacher, Kit Yee Au-Yeung, Simon Tam
article en
1 citations

Abstract

Introduction: Magnetocardiography (MCG) has potential to significantly improve cardiac disease diagnosis, but adoption in clinical practice is hindered by high cost and large footprints of traditional systems. Hence, we developed a bedside, non-contact MCG system that utilizes quantum magnetometers and AI methods to extract validated cardiac biomarkers, while rejecting ambient magnetic interference. Goal: To investigate the safety and efficacy of the bedside MCG device in identifying non-ST-segment elevation myocardial infarction (N-STEMI) among patients from an urban emergency department. Methods: The MCG system is a custom prototype with 26 optically pumped magnetometers - quantum sensors that measure cardiac magnetic fields with picoTesla sensitivity. We recruited a diverse sample of 78 adult patients (72 with analyzable data) presenting to the ED with chest pain symptoms suggestive of ACS who were not experiencing STEMI (mean age=56 years; 64% male; 11% Asian, 28% Black, 7% American Indian/Alaska Native, 44% White, 1% Native Hawaiian/Pacific Islander, 9% other/unknown; 6 technically unusable recordings, 8%). A 5-minute MCG was recorded within 2 hours of an initial 12-lead ECG. Signal processing and AI algorithms were used to remove ambient interference and recover cardiac signal. Literature-based MCG markers were inputted to a classification and regression tree (CART) model to classify patients as NSTEMI ACS rule-in or rule-out. Results: The CART model successfully discriminated clinically determined ACS rule-in patients (n=7) from rule-outs (n=65) with sensitivity=86% and specificity=92%. The most predictive MCG markers were the field pattern angle difference between R- and T-wave maximum, the power ratio between the R- and T-waves, and the field maximum to minimum ratio. No adverse events were reported. Conclusions: MCG is a promising, non-contact diagnostic tool for emergency physicians diagnosing suspected ACS cases. This pilot study shows that a bedside, quantum-sensing MCG that utilizes AI has the potential to provide safe and accurate diagnostic results, and it is feasible to integrate the device into the ED workflow.

CirculationVol. 150(Suppl_1)
Providence College (US), Mount Sinai Hospital (US), Icahn School of Medicine at Mount Sinai (US)
Openalex Percentile: Top 51%
Non-Invasive Vital Sign Monitoring
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.