Reliability of Commercial TOPCon PV Modules—An Extensive Comparative Study

ABSTRACT Tunnel oxide passivated contact (TOPCon) is poised to emerge as the predominant technology in photovoltaic (PV) cells, yet accelerated aging tests point towards significant reliability issues that remain unresolved. This study conducts a comparative analysis of 20 TOPCon PV module types, utilizing a range of electrical characterization and accelerated aging assessments. This investigation provides a detailed evaluation of the electrical performance, resulting in an energy rating of the modules, establishing a benchmark for cutting‐edge TOPCon technology. While some failure modes, such as LeTID, appear to be noncritical, the findings confirm previously identified degradation pathways in TOPCon modules due to moisture penetration. During UV exposure, a novel degradation pattern was observed during the indoor tests, showing severe losses (up to −12% after 120 kWh/m 2 ), followed by recovery after humidity freeze testing, which may influence outdoor performance and the outcomes of certification tests (IEC 61730‐2, Sequence B). The results highlight the areas of need for more targeted testing and technological refinement.

Authors

Institutions

Publication Details

Journal
Progress in Photovoltaics Research and Applications
Published
2024-11-13
DOI
https://doi.org/10.1002/pip.3868
Citations
20
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
2.05
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of Commercial TOPCon PV Modules—An Extensive Comparative Study

Daniel Philipp, Ingrid Hädrich, Ulli Kräling, Paul Gebhardt et al.
20 citations
Progress in Photovoltaics Research and Applications
Photovoltaic System Optimization Techniques
2.05
article

Reliability of Commercial TOPCon PV Modules—An Extensive Comparative Study

Daniel Philipp, Ingrid Hädrich, Ulli Kräling, Paul Gebhardt, Esther Fokuhl
article en
20 citations

Abstract

ABSTRACT Tunnel oxide passivated contact (TOPCon) is poised to emerge as the predominant technology in photovoltaic (PV) cells, yet accelerated aging tests point towards significant reliability issues that remain unresolved. This study conducts a comparative analysis of 20 TOPCon PV module types, utilizing a range of electrical characterization and accelerated aging assessments. This investigation provides a detailed evaluation of the electrical performance, resulting in an energy rating of the modules, establishing a benchmark for cutting‐edge TOPCon technology. While some failure modes, such as LeTID, appear to be noncritical, the findings confirm previously identified degradation pathways in TOPCon modules due to moisture penetration. During UV exposure, a novel degradation pattern was observed during the indoor tests, showing severe losses (up to −12% after 120 kWh/m 2 ), followed by recovery after humidity freeze testing, which may influence outdoor performance and the outcomes of certification tests (IEC 61730‐2, Sequence B). The results highlight the areas of need for more targeted testing and technological refinement.

Progress in Photovoltaics Research and ApplicationsVol. 33(12)
Fraunhofer Institute for Solar Energy Systems (DE)
Affordable and clean energy
Openalex Percentile: Top 13%
Photovoltaic System Optimization Techniques
2.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.