Abstract 4141884: Fully Automatic Quantification of the Aortic Root in 4D Transesophageal Echocardiography
Introduction: Aortic root (AoR) morphology and dynamics are integral to understanding aortic valve function and planning patient-specific aortic interventions with transesophageal echocardiography (TEE). Modeling the AoR in time-varying 3D data is advantageous over conventional 2D cross-sectional analysis. However, manual segmentation of the AoR in 3D relies on a learning curve and takes up to 1.5 hours per volume. We hypothesize that the AoR can be rapidly and accurately segmented and quantified fully automatically with deep learning in pre-operative 4D TEE. Methods: Pre-operative TEE from both bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) patients were semi-automatically segmented and manually verified. A nnU-Net model was trained, validated, and tested with 74 TEE time-series images (46 BAV, 28 TAV) consisting of 1971 individual 3D volumes (60/40% training/testing split) from 2 institutions. The Dice similarity coefficient and average mesh-to-mesh distances were compared to interobserver variability between multiple manual tracers. AoR volume and diameters were automatically computed. Quantification agreement between model-generated and semi-automatic segmentations was analyzed with the intraclass correlation coefficient and Student’s t-test. Results: A representative automatic segmentation and quantification of the AoR is shown in Figure 1a-c. Quantification agreement between automatic and manual segmentations for all test data are shown in Figure 1d. Measurements on automatic segmentations have strong agreement with measurements on manual segmentations (ICC > 0.95). Automatic segmentation results are insignificantly different from interobserver tracings (p > 0.01), suggesting that a reliable AoR segmentation can be produced in inference time as little as 1-2 seconds per 3D volume (Figure 1e-g). Conclusions: The proposed deep learning method rapidly produces AoR segmentations and quantifications that are comparable to manual tracing. This framework can aid in population-based comparison of BAV and TAV roots and facilitate patient-specific AoR assessment for surgical planning. In the future, leaflet segmentations can be incorporated for analysis of the full aortic valve apparatus in TEE.
Authors
- Nimesh D. Desai (ORCID: https://orcid.org/0000-0002-4456-5674)
- Joseph E. Bavaria (ORCID: https://orcid.org/0000-0001-7145-0453)
- Matthew A. Jolley (ORCID: https://orcid.org/0000-0002-5626-0130)
- Jilei Hao
- Trevor Chan (ORCID: https://orcid.org/0000-0003-2327-5050)
- Lourdes Al Ghofaily
- Nathanael Tran
- Natalie Yushkevich
- Alison M. Pouch (ORCID: https://orcid.org/0000-0001-8854-5301)
- Silvani Amin
- Young Woo Do (ORCID: https://orcid.org/0000-0001-9725-9163)
- Albert T. Cheung
Institutions
- Children's Hospital of Philadelphia (US)
- Thomas Jefferson University (US)
- Massachusetts General Hospital (US)
- University of Pennsylvania (US)
Publication Details
- Journal
- Circulation
- Published
- 2024-11-12
- DOI
- https://doi.org/10.1161/circ.150.suppl_1.4141884
- Citations
- 1
- Primary Topic
- Cardiac Imaging and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.40