Abstract 4141975: Feasibility of Using Wearables to Obtain High-Fidelity ECG Signals for Cardiovascular Disease Screening in Palestinian Refugees in Jordan

Background: Refugee populations often experience high rates of cardiovascular disease (CVD). Factors such as significant physiological stress, trauma, limited access to healthcare, substance abuse, and poor lifestyle choices contribute to disease progression and an increased incidence of cardiovascular events. We sought to evaluate the feasibility of using wearables to obtain high-fidelity ECG signals for CVD screening in refugees in Jordan. Methods: This observational cross-sectional study involved outpatients at one of four regional United Nations’ primary care clinics for Palestinian refugee in Jordan. Research assistants collected health histories from consented patients and recorded a 30-second, 6-lead ECG using a handheld, Bluetooth-enabled, wearable device (KardiaMobile 6L, AliveCor Inc., Mountain View, CA, USA). The digital ECG signals were stored on the Bluetooth-synced mobile device and then exported to a cloud server for offline analysis. The raw ECG recordings were preprocessed, and a single median beat was calculated per lead. Waveforms were segmented, and duration and amplitude measures were determined using a previously validated custom algorithm (University of Pittsburgh, PA, USA). All ECG recordings were reviewed by an independent physician. Result: The sample included 31 patients (age 52±13, 64% Females). Risk factors were prevalent in this group, including hypertension (74%), high cholesterol (65%), diabetes (64%), in-camp living (33%), and smoking (30%). Figure 1 shows the population-averaged median beat with 99% CI distribution of this sample. Mean QRS duration was 95±23 ms (range 53−150) and QTc interval was 403±53 (range 267−513). Most patients were in normal sinus rhythm (84%), and remaining patients were in atrial fibrillation or flutter (16%). Other clinically significant abnormalities included non-specific ST-T changes (9.7%), left bundle branch block (1.6%), and LVH with left ventricular strain (1.6%). Conclusion: This pilot study demonstrated that it is feasible to obtain high fidelity ECG signals using wearables to screen for CVD in refugees. Such affordable, noninvasive, point-of-care screening tools could enable early diagnosis and treatment in these patients.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4141975
Primary Topic
Cardiovascular Health and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4141975: Feasibility of Using Wearables to Obtain High-Fidelity ECG Signals for Cardiovascular Disease Screening in Palestinian Refugees in Jordan

Jafar Alasad Alshraideh, Salah S. Al‐Zaiti, Ervin Sejdić, Hadeel Atoum et al.
Circulation
Cardiovascular Health and Risk Factors
article

Abstract 4141975: Feasibility of Using Wearables to Obtain High-Fidelity ECG Signals for Cardiovascular Disease Screening in Palestinian Refugees in Jordan

Jafar Alasad Alshraideh, Salah S. Al‐Zaiti, Ervin Sejdić, Hadeel Atoum, Rui Ji, Hamzah Alduraidi, Mutaz Abu-Hananneh
article en

Abstract

Background: Refugee populations often experience high rates of cardiovascular disease (CVD). Factors such as significant physiological stress, trauma, limited access to healthcare, substance abuse, and poor lifestyle choices contribute to disease progression and an increased incidence of cardiovascular events. We sought to evaluate the feasibility of using wearables to obtain high-fidelity ECG signals for CVD screening in refugees in Jordan. Methods: This observational cross-sectional study involved outpatients at one of four regional United Nations’ primary care clinics for Palestinian refugee in Jordan. Research assistants collected health histories from consented patients and recorded a 30-second, 6-lead ECG using a handheld, Bluetooth-enabled, wearable device (KardiaMobile 6L, AliveCor Inc., Mountain View, CA, USA). The digital ECG signals were stored on the Bluetooth-synced mobile device and then exported to a cloud server for offline analysis. The raw ECG recordings were preprocessed, and a single median beat was calculated per lead. Waveforms were segmented, and duration and amplitude measures were determined using a previously validated custom algorithm (University of Pittsburgh, PA, USA). All ECG recordings were reviewed by an independent physician. Result: The sample included 31 patients (age 52±13, 64% Females). Risk factors were prevalent in this group, including hypertension (74%), high cholesterol (65%), diabetes (64%), in-camp living (33%), and smoking (30%). Figure 1 shows the population-averaged median beat with 99% CI distribution of this sample. Mean QRS duration was 95±23 ms (range 53−150) and QTc interval was 403±53 (range 267−513). Most patients were in normal sinus rhythm (84%), and remaining patients were in atrial fibrillation or flutter (16%). Other clinically significant abnormalities included non-specific ST-T changes (9.7%), left bundle branch block (1.6%), and LVH with left ventricular strain (1.6%). Conclusion: This pilot study demonstrated that it is feasible to obtain high fidelity ECG signals using wearables to screen for CVD in refugees. Such affordable, noninvasive, point-of-care screening tools could enable early diagnosis and treatment in these patients.

CirculationVol. 150(Suppl_1)
University of Jordan (JO), University of Pittsburgh (US), University of Toronto (CA)
Good health and well-being
Openalex Percentile: Top 62%
Cardiovascular Health and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.