Abstract 4142099: Deep Learning Quantification of Aortic Compliance from Parasternal Long-Axis Echocardiograms

Introduction: Aortic compliance is crucial for maintaining diastolic blood pressure and systemic perfusion throughout the cardiac cycle. Echocardiography is widely used for cardiovascular imaging but has limited precision in clinical phenotyping of aortic compliance. Hypothesis: We hypothesized that a deep learning approach can quantify aortic compliance by precision characterization of the aortic root in parasternal long-axis echocardiogram videos and that this deep learning measured aortic compliance would correlate with aspects of thoracic aortic repair. Aims: Develop a high precision deep learning model for quantifying aortic compliance from echocardiogram videos and explore associations with surgical repair. Methods: We used 51730 PLAX echocardiogram videos from Cedars-Sinai Medical Center, divided into training (46188), validation (5035), and test (507) cohorts. The DeepLabv3 architecture with a 50-layer residual network backbone was used for frame-level segmentation of the aortic root. Strain was obtained by dividing the change in root diameter by the minimum diameter during each cardiac cycle. Evaluation of measurements was performed on a separate cohort of 33 patients who underwent endovascular repair of the thoracic aorta. Results: The model accurately measured aortic root diameter with a mean absolute error (MAE) of 2.5mm comparing favorably with clinical inter-observer variability (MAE of 2.9mm, p=0.010). Exploratory data analysis showed increasing aortic root strain after endovascular repair (n=12, p=0.084) but no clear trends after combined endovascular and open repair (n=21, p=0.852). Aortic strain was lower in patients with prior abdominal surgery (n=12, p=0.001) and dissection that underwent repair (n=14, p=0.099), and postoperative aortic strains were lower in patients requiring surgery within 30 days (n=7, p=0.024). Conclusion: A deep learning workflow can measure aortic root diameter and identify changes in aortic compliance with higher precision than human assessment. Trends in preoperative and postoperative aortic strain in patients undergoing endovascular repair suggest utility of aortic strain phenotyping for prognosticating clinical outcomes.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4142099
Primary Topic
Cardiovascular Disease and Adiposity
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4142099: Deep Learning Quantification of Aortic Compliance from Parasternal Long-Axis Echocardiograms

Elizabeth L. Chou, Grant Duffy, Eileen Lu, Miloš Vukadinovic et al.
Circulation
Cardiovascular Disease and Adiposity
article

Abstract 4142099: Deep Learning Quantification of Aortic Compliance from Parasternal Long-Axis Echocardiograms

Elizabeth L. Chou, Grant Duffy, Eileen Lu, Miloš Vukadinovic, Shruthi Nammalwar, David Ouyang, Justin Rhee
article en

Abstract

Introduction: Aortic compliance is crucial for maintaining diastolic blood pressure and systemic perfusion throughout the cardiac cycle. Echocardiography is widely used for cardiovascular imaging but has limited precision in clinical phenotyping of aortic compliance. Hypothesis: We hypothesized that a deep learning approach can quantify aortic compliance by precision characterization of the aortic root in parasternal long-axis echocardiogram videos and that this deep learning measured aortic compliance would correlate with aspects of thoracic aortic repair. Aims: Develop a high precision deep learning model for quantifying aortic compliance from echocardiogram videos and explore associations with surgical repair. Methods: We used 51730 PLAX echocardiogram videos from Cedars-Sinai Medical Center, divided into training (46188), validation (5035), and test (507) cohorts. The DeepLabv3 architecture with a 50-layer residual network backbone was used for frame-level segmentation of the aortic root. Strain was obtained by dividing the change in root diameter by the minimum diameter during each cardiac cycle. Evaluation of measurements was performed on a separate cohort of 33 patients who underwent endovascular repair of the thoracic aorta. Results: The model accurately measured aortic root diameter with a mean absolute error (MAE) of 2.5mm comparing favorably with clinical inter-observer variability (MAE of 2.9mm, p=0.010). Exploratory data analysis showed increasing aortic root strain after endovascular repair (n=12, p=0.084) but no clear trends after combined endovascular and open repair (n=21, p=0.852). Aortic strain was lower in patients with prior abdominal surgery (n=12, p=0.001) and dissection that underwent repair (n=14, p=0.099), and postoperative aortic strains were lower in patients requiring surgery within 30 days (n=7, p=0.024). Conclusion: A deep learning workflow can measure aortic root diameter and identify changes in aortic compliance with higher precision than human assessment. Trends in preoperative and postoperative aortic strain in patients undergoing endovascular repair suggest utility of aortic strain phenotyping for prognosticating clinical outcomes.

CirculationVol. 150(Suppl_1)
Cedars-Sinai Medical Center (US)
Good health and well-being
Openalex Percentile: Top 62%
Cardiovascular Disease and Adiposity
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.