Abstract 4143309: Fluorescence-Labeled Very Low-Density Lipoproteins (VLDLs) Clearance Method for the Assessment of Dynamic VLDLs Function in Mice

Introduction: Very Low-Density Lipoproteins (VLDLs) serve as crucial transporters of triglycerides (TG) and cholesterol (C) from the liver to peripheral tissues, thereby contributing significantly to metabolic disorders such as atherosclerosis. Assessing the dynamic of VLDLs function involves evaluating its clearance from the bloodstream and distribution across various organs. Although VLDLs clearance has been extensively studied using dual radioactive isotopes 3 H and 14 C to label TG and C, this method requires large amounts of expensive tracers, compliance, and technical complexities. Our objective is to design and test a fluorescence-based approach to simultaneously assess and visualize VLDLs kinetics in a mouse model. Through this approach, we aim to unravel the intricate interplay between thermogenesis and VLDLs metabolism and provide insights into their collective influence on the progression of atherosclerosis in vivo. Method: Fluorescence-labeled VLDLs-like TG-rich nanoparticles (F-VLDLs) were prepared at various intensity by incorporating lissamine rhodamine-TG (Rhoda-TG, 1-5% of total TG) and TopFluor®-C (TopF-C, 20-80% of total C) to a mixture containing glycerol trioleate (7mg), egg yolk phosphatidylcholine (2.3mg), lysophosphatidylcholine (0.23mg), cholesteryl oleate (0.3mg), cholesterol (0.2mg) and kolliphor HS15 (2mg). B6 mice were fasted for 4 hours and injected via the tail vein with various intensities of F-VLDLs (2 mg TG/mouse). Blood samples were collected at 5-, 10- and 15-min post-injection to determine the plasma clearance of Rhoda-TG and TopF-C, after which mice were euthanized, and tissues harvested and imaged using an IVIS® spectrum in vivo imaging system. Results: The mean particle size of F-VLDLs was 80nm, with polydispersity index values of about 0.2. The Zeta potential of freshly made F-VLDLs was about −20 mV. In B6 mice, both Rhoda-TG and TopF-C signal intensities peaked at 5 minutes post-injection and subsequently declined in an intensity-dependent manner. In the collected tissues, Rhoda-TG and TopF-C intensity was as follows: liver>brown fat>subcutaneous white fat >visceral white fat. Conclusion: We have designed novel fluorescence-labeled VLDVs-like particles as a viable approach for quantifying and visualizing dynamic VLDLs-TG and C flux in vivo. This approach will facilitate the assessment of how various metabolic interventions impact VLDLs metabolism and atherosclerosis.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4143309
Primary Topic
Atherosclerosis and Cardiovascular Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4143309: Fluorescence-Labeled Very Low-Density Lipoproteins (VLDLs) Clearance Method for the Assessment of Dynamic VLDLs Function in Mice

Shane Scoggin, Yujiao Zu, Mandana Pahlavani, Naïma Moustaïd‐Moussa et al.
Circulation
Atherosclerosis and Cardiovascular Diseases
article

Abstract 4143309: Fluorescence-Labeled Very Low-Density Lipoproteins (VLDLs) Clearance Method for the Assessment of Dynamic VLDLs Function in Mice

Shane Scoggin, Yujiao Zu, Mandana Pahlavani, Naïma Moustaïd‐Moussa, Tatum Walker
article en

Abstract

Introduction: Very Low-Density Lipoproteins (VLDLs) serve as crucial transporters of triglycerides (TG) and cholesterol (C) from the liver to peripheral tissues, thereby contributing significantly to metabolic disorders such as atherosclerosis. Assessing the dynamic of VLDLs function involves evaluating its clearance from the bloodstream and distribution across various organs. Although VLDLs clearance has been extensively studied using dual radioactive isotopes 3 H and 14 C to label TG and C, this method requires large amounts of expensive tracers, compliance, and technical complexities. Our objective is to design and test a fluorescence-based approach to simultaneously assess and visualize VLDLs kinetics in a mouse model. Through this approach, we aim to unravel the intricate interplay between thermogenesis and VLDLs metabolism and provide insights into their collective influence on the progression of atherosclerosis in vivo. Method: Fluorescence-labeled VLDLs-like TG-rich nanoparticles (F-VLDLs) were prepared at various intensity by incorporating lissamine rhodamine-TG (Rhoda-TG, 1-5% of total TG) and TopFluor®-C (TopF-C, 20-80% of total C) to a mixture containing glycerol trioleate (7mg), egg yolk phosphatidylcholine (2.3mg), lysophosphatidylcholine (0.23mg), cholesteryl oleate (0.3mg), cholesterol (0.2mg) and kolliphor HS15 (2mg). B6 mice were fasted for 4 hours and injected via the tail vein with various intensities of F-VLDLs (2 mg TG/mouse). Blood samples were collected at 5-, 10- and 15-min post-injection to determine the plasma clearance of Rhoda-TG and TopF-C, after which mice were euthanized, and tissues harvested and imaged using an IVIS® spectrum in vivo imaging system. Results: The mean particle size of F-VLDLs was 80nm, with polydispersity index values of about 0.2. The Zeta potential of freshly made F-VLDLs was about −20 mV. In B6 mice, both Rhoda-TG and TopF-C signal intensities peaked at 5 minutes post-injection and subsequently declined in an intensity-dependent manner. In the collected tissues, Rhoda-TG and TopF-C intensity was as follows: liver>brown fat>subcutaneous white fat >visceral white fat. Conclusion: We have designed novel fluorescence-labeled VLDVs-like particles as a viable approach for quantifying and visualizing dynamic VLDLs-TG and C flux in vivo. This approach will facilitate the assessment of how various metabolic interventions impact VLDLs metabolism and atherosclerosis.

CirculationVol. 150(Suppl_1)
Texas Tech University (US), Texas Woman's University (US)
Openalex Percentile: Top 74%
Atherosclerosis and Cardiovascular Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.