Abstract 4143416: Optical Absorption Figure of Merit for Photoplethysmography-Based Cuffless Monitoring of Blood Pressure Varies Across a Diversity of Skin Tones in the Fitzpatrick Scale

Introduction: Well-publicized studies have shown that photoplethysmography (PPG), a key technology for pulse oximeters and consumer wearables, may have limitations for users with darker skin tones. This study assessed the correlation between skin tone and figures of merit for PPG sensing in a multiwavelength, reflection-mode, fingertip-worn PPG device. The device measures optical signals on the underside of the hand, where melanin density is relatively low; thus, this study hypothesized that the figures of merit would show an insignificant correlation with skin tone. Methods and Results: A study at Houston Cardiology Consultants saw trained professionals tend to 174 participants (Table 1). Subjects wore a multiwavelength, reflection-mode, PPG-based fingertip sensor. Subject metadata, including skin tone, were collected manually. PPG datasets were analyzed by Valencell, Inc. using the company’s standard figures of merit: AC/DC ratio, Signal-to-Noise-And-Distortion (SINAD), and Relative Peak Ratio (RPR). SINAD and RPR represent motion-artifact resistance and hemodynamic consistency, respectively. The AC/DC ratio measures the strength of the pulsatile PPG waveform against unwanted optical scatter due to melanin and other skin chromophores. Using the Fitzpatrick Scale to quantify skin tone (Figure 1), its correlation with these figures of merit was assessed. No correlation was found between the Fitzpatrick value and SINAD or RPR across optical wavelengths. However, a strong correlation between the Fitzpatrick value and AC/DC ratio was observed for all wavelengths, with the green AC/DC ratio showing the highest correlation (Table 2). Conclusion: The observed disparity in AC/DC ratio with skin tone must be considered when developing PPG-based physiological monitors to ensure they operate effectively across all Fitzpatrick values, even when these monitors target skin regions with relatively low melanin density. Engineering approaches that rely solely on green wavelengths of light, the most commonly used in consumer wearables, will face greater challenges than those utilizing longer wavelengths.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4143416
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4143416: Optical Absorption Figure of Merit for Photoplethysmography-Based Cuffless Monitoring of Blood Pressure Varies Across a Diversity of Skin Tones in the Fitzpatrick Scale

Jonathan Reyes-Rivera, Yulissa Delgado, M. E. Aumer, Sami Farooqui et al.
Circulation
Non-Invasive Vital Sign Monitoring
article

Abstract 4143416: Optical Absorption Figure of Merit for Photoplethysmography-Based Cuffless Monitoring of Blood Pressure Varies Across a Diversity of Skin Tones in the Fitzpatrick Scale

Jonathan Reyes-Rivera, Yulissa Delgado, M. E. Aumer, Sami Farooqui, Asif Ali, Steven LeBoeuf, Anna Trawick
article en

Abstract

Introduction: Well-publicized studies have shown that photoplethysmography (PPG), a key technology for pulse oximeters and consumer wearables, may have limitations for users with darker skin tones. This study assessed the correlation between skin tone and figures of merit for PPG sensing in a multiwavelength, reflection-mode, fingertip-worn PPG device. The device measures optical signals on the underside of the hand, where melanin density is relatively low; thus, this study hypothesized that the figures of merit would show an insignificant correlation with skin tone. Methods and Results: A study at Houston Cardiology Consultants saw trained professionals tend to 174 participants (Table 1). Subjects wore a multiwavelength, reflection-mode, PPG-based fingertip sensor. Subject metadata, including skin tone, were collected manually. PPG datasets were analyzed by Valencell, Inc. using the company’s standard figures of merit: AC/DC ratio, Signal-to-Noise-And-Distortion (SINAD), and Relative Peak Ratio (RPR). SINAD and RPR represent motion-artifact resistance and hemodynamic consistency, respectively. The AC/DC ratio measures the strength of the pulsatile PPG waveform against unwanted optical scatter due to melanin and other skin chromophores. Using the Fitzpatrick Scale to quantify skin tone (Figure 1), its correlation with these figures of merit was assessed. No correlation was found between the Fitzpatrick value and SINAD or RPR across optical wavelengths. However, a strong correlation between the Fitzpatrick value and AC/DC ratio was observed for all wavelengths, with the green AC/DC ratio showing the highest correlation (Table 2). Conclusion: The observed disparity in AC/DC ratio with skin tone must be considered when developing PPG-based physiological monitors to ensure they operate effectively across all Fitzpatrick values, even when these monitors target skin regions with relatively low melanin density. Engineering approaches that rely solely on green wavelengths of light, the most commonly used in consumer wearables, will face greater challenges than those utilizing longer wavelengths.

CirculationVol. 150(Suppl_1)
Valencell (United States) (US), The University of Texas Health Science Center at Houston (US)
Openalex Percentile: Top 81%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.