Abstract 4143715: An unusual cause for very early dysfunction of a bileaflet mechanical mitral valve (when push comes to shove)

Description of Case: A 44-year-old man with a history of mitral valve prolapse and mitral valve repair with triangular resection and partial annuloplasty ring placement eight years prior to presenting with dyspnea and decreased exercise tolerance. His TTE showed severe mitral stenosis with thickening of the posterior mitral leaflet. A redo sternotomy with mitral valve replacement was planned. Intra-procedurally, it was noted that the previous partial annuloplasty ring was impinging on the proximal portion of the posterior leaflet resulting in restricted motion, there was also fusion of the commissures. The partial annuloplasty ring was removed, and a 25 mm On-X mechanical valve was implanted in the mitral position. At the end of surgery, after the patient was off cardiopulmonary bypass, he developed severe hypoxia, and he was started on inhaled nitric oxide. Due to the concern for poor lung compliance, his sternotomy was not closed, and packing was placed in the anterior mediastinum and covered with an antimicrobial incise drape. In the surgical ICU, he became hypotensive and required ionotropic and vasopressor support. After diuresis, the surgical team decided to bring him back to the operating room on postoperative day 3 with concerns for mechanical valve dysfunction with the possibility of redo valve replacement in addition to closure of the anterior mediastinum and sternum. Intraoperative TEE showed that the anterolateral prosthetic mitral valve disc was fixed in the open position. There was no thrombus seen on the leaflets or the valve apparatus. On removal of the anterior mediastinal packing, the valve leaflet started functioning normally. The chest was closed without the need to redo the mechanical mitral valve. Discussion: Mechanical valve dysfunction can be either endogenous or exogenous. Our case represents a unique cause of early mechanical mitral valve dysfunction related to external compression by surgical packing impinging on the anterolateral disk inferior to the left atrial appendage from the ventricular side. Intraoperative TEE with 3-D played a vital role in the recognition of this complication and the prevention of redo valve replacement.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4143715
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4143715: An unusual cause for very early dysfunction of a bileaflet mechanical mitral valve (when push comes to shove)

Brian Kliewer, Luis Velazco, Omar Khdeir, Kofi B. Vandyck et al.
Circulation
Cardiac Valve Diseases and Treatments
article

Abstract 4143715: An unusual cause for very early dysfunction of a bileaflet mechanical mitral valve (when push comes to shove)

Brian Kliewer, Luis Velazco, Omar Khdeir, Kofi B. Vandyck, Chittur A. Sivaram
article en

Abstract

Description of Case: A 44-year-old man with a history of mitral valve prolapse and mitral valve repair with triangular resection and partial annuloplasty ring placement eight years prior to presenting with dyspnea and decreased exercise tolerance. His TTE showed severe mitral stenosis with thickening of the posterior mitral leaflet. A redo sternotomy with mitral valve replacement was planned. Intra-procedurally, it was noted that the previous partial annuloplasty ring was impinging on the proximal portion of the posterior leaflet resulting in restricted motion, there was also fusion of the commissures. The partial annuloplasty ring was removed, and a 25 mm On-X mechanical valve was implanted in the mitral position. At the end of surgery, after the patient was off cardiopulmonary bypass, he developed severe hypoxia, and he was started on inhaled nitric oxide. Due to the concern for poor lung compliance, his sternotomy was not closed, and packing was placed in the anterior mediastinum and covered with an antimicrobial incise drape. In the surgical ICU, he became hypotensive and required ionotropic and vasopressor support. After diuresis, the surgical team decided to bring him back to the operating room on postoperative day 3 with concerns for mechanical valve dysfunction with the possibility of redo valve replacement in addition to closure of the anterior mediastinum and sternum. Intraoperative TEE showed that the anterolateral prosthetic mitral valve disc was fixed in the open position. There was no thrombus seen on the leaflets or the valve apparatus. On removal of the anterior mediastinal packing, the valve leaflet started functioning normally. The chest was closed without the need to redo the mechanical mitral valve. Discussion: Mechanical valve dysfunction can be either endogenous or exogenous. Our case represents a unique cause of early mechanical mitral valve dysfunction related to external compression by surgical packing impinging on the anterolateral disk inferior to the left atrial appendage from the ventricular side. Intraoperative TEE with 3-D played a vital role in the recognition of this complication and the prevention of redo valve replacement.

CirculationVol. 150(Suppl_1)
Oklahoma City University (US), Orthopaedic Center of Vero Beach (US)
Good health and well-being
Openalex Percentile: Top 62%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.