Abstract 4144041: AI-Based ECG Denoising Improves Smartwatch ECG Interpretation

Background/Aim: Smartwatch ECGs (SW-ECG) have emerged as a noninvasive solution to assess abnormal heart rhythms such as atrial fibrillation (AF). However, SW-ECGs recorded in free-living settings are often noisy and yield Inconclusive results from automated AF detection algorithms. We developed a deep learning model to denoise single-lead ECGs and reduce the number of inconclusive tracings that require manual overread. Methods: Using the MIMIC-III waveform database (N=2,988 patients, 10.1% AF), we created pairs of clean (high signal quality index based on dynamic beat template matching) 30-sec, single-lead ECGs and their noisy counterparts by injecting various combinations of noise including baseline wander, electrode motion and synthetic noise of different colors. The noisy ECGs served as the input to a 1D U-Net that was trained to reconstruct the corresponding clean ECG (AI-ECG-Denoise). We evaluated the performance of an offline automated ECG classifier before and after applying AI-ECG-Denoise on a held-out test set from MIMIC-III (N=34 patients, 52.9% AF) comprising 1,000 single-lead ECGs that we injected with noise at different signal-to-noise ratios (SNRs), and an external test set of 701 free-living SW-ECGs from 115 healthy consented study subjects using a prototype watch. Results: In the MIMIC-III test set, AI-ECG-Denoise significantly reduced the number of Inconclusive ECG results across noisy ECGs with SNRs ranging from -10 to 30 dB with no significant difference in sensitivity and specificity for AF down to an SNR of 3 dB. In the external wrist-worn test set, AI-ECG-Denoise significantly reduced the number of Inconclusive free-living SW-ECG Interpretations (p<0.001) by 33.3% [95% CI: 25.1, 39.9], recategorizing the majority as Normal, with no significant difference in specificity per McNemar’s test (99.2% [98.4, 99.8] before and 98.8% [97.8, 99.6] after denoising). Conclusion: A deep learning model for ECG denoising decreased the number of Inconclusive results in the detection of AF from SW-ECGs. This could help reduce user anxiety and limit the overreading time spent by the physicians.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4144041
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4144041: AI-Based ECG Denoising Improves Smartwatch ECG Interpretation

Tony Faranesh, Paolo Di Achille, Jacqueline Baras Shreibati, Ming‐Zher Poh et al.
Circulation
ECG Monitoring and Analysis
article

Abstract 4144041: AI-Based ECG Denoising Improves Smartwatch ECG Interpretation

Tony Faranesh, Paolo Di Achille, Jacqueline Baras Shreibati, Ming‐Zher Poh, Tanay Vakharia, Shun Liao
article en

Abstract

Background/Aim: Smartwatch ECGs (SW-ECG) have emerged as a noninvasive solution to assess abnormal heart rhythms such as atrial fibrillation (AF). However, SW-ECGs recorded in free-living settings are often noisy and yield Inconclusive results from automated AF detection algorithms. We developed a deep learning model to denoise single-lead ECGs and reduce the number of inconclusive tracings that require manual overread. Methods: Using the MIMIC-III waveform database (N=2,988 patients, 10.1% AF), we created pairs of clean (high signal quality index based on dynamic beat template matching) 30-sec, single-lead ECGs and their noisy counterparts by injecting various combinations of noise including baseline wander, electrode motion and synthetic noise of different colors. The noisy ECGs served as the input to a 1D U-Net that was trained to reconstruct the corresponding clean ECG (AI-ECG-Denoise). We evaluated the performance of an offline automated ECG classifier before and after applying AI-ECG-Denoise on a held-out test set from MIMIC-III (N=34 patients, 52.9% AF) comprising 1,000 single-lead ECGs that we injected with noise at different signal-to-noise ratios (SNRs), and an external test set of 701 free-living SW-ECGs from 115 healthy consented study subjects using a prototype watch. Results: In the MIMIC-III test set, AI-ECG-Denoise significantly reduced the number of Inconclusive ECG results across noisy ECGs with SNRs ranging from -10 to 30 dB with no significant difference in sensitivity and specificity for AF down to an SNR of 3 dB. In the external wrist-worn test set, AI-ECG-Denoise significantly reduced the number of Inconclusive free-living SW-ECG Interpretations (p<0.001) by 33.3% [95% CI: 25.1, 39.9], recategorizing the majority as Normal, with no significant difference in specificity per McNemar’s test (99.2% [98.4, 99.8] before and 98.8% [97.8, 99.6] after denoising). Conclusion: A deep learning model for ECG denoising decreased the number of Inconclusive results in the detection of AF from SW-ECGs. This could help reduce user anxiety and limit the overreading time spent by the physicians.

CirculationVol. 150(Suppl_1)
Google (United States) (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 62%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.