Abstract 4143899: cusp-overlap view versus three cusp coplanar view during transcatheter aortic valve replacement using self-expandable valves: A meta-analysis of 5947 patients.

Background & Objectives: Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for most patients with symptomatic severe aortic stenosis. We conducted this systematic review, and meta-analysis to compare the efficacy and procedural outcomes of using the cusp overlap technique (COT) versus the standard three-cusp technique during self-expandable valves implantation for the management of aortic stenosis. Methodology: We systematically searched PubMed, Scopus, Embase, Cochrane, and Web of Science (WOS) from inception to March 5, 2024, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. To estimate the effect size, dichotomous outcomes were pooled as risk ratio (RR), and continuous outcomes were pooled as mean difference (MD) with their respective 95% confidence interval (CI). Results: We included seventeen studies in our systematic review and meta-analysis with a total of 3129 patients in cusp-overlap technique (COT) arm and 2818 patients in standard technique (ST) arm. The rate of 30-day mortality was significantly decreased in COT compared with ST (RR = 0.61; 95% CI: [0.37–1.00], P = 0.05). Regarding conduction abnormalities, COT was related to lower risk of complete atrioventricular (AV) block (RR = 0.51; 95% CI: [0.37–0.69], P < 0.01), reduced likelihood of left bundle branch block (RR = 0.77; 95% CI: [0.61–0.97], P = 0.03) and permanent pacemaker implantation (PPI) (RR = 0.56; 95% CI: [0.46–0.70], P < 0.01). There was also lower likelihood of major and life-threatening bleeding with the COT compared to ST (RR = 0.60; 95% CI: [0.46–0.79], P < 0.01). Our analysis also showed that COT was associated with significantly lower implantation depth compared with ST (MD = -1.00; 95% Cl: [-1.83 to -0.17], P = 0.02). Procedural success was similar between COT and ST (RR = 1.01; 95% CI: [0.98–1.04], P = 0.42). Major vascular complications (RR = 0.90; 95% CI: [0.61–1.33], P = 0.61), and mild to severe paravalvular leak (RR = 1.00; 95% CI: [0.66–1.51], P = 1.00) were also comparable between COT and ST. Conclusion: Our study findings suggest that COT offers several advantages over ST, including reduced 30-day mortality and decreased bleeding complications, without compromising long-term outcomes or increasing procedural complications. The COT most importantly lower risk of conduction abnormalities, and hence permanent pacemaker implantation.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4143899
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4143899: cusp-overlap view versus three cusp coplanar view during transcatheter aortic valve replacement using self-expandable valves: A meta-analysis of 5947 patients.

Serge Sicouri, Ahmed K. Awad, Ahmed R. Gonnah, Ramlawi Basel et al.
Circulation
Cardiac Valve Diseases and Treatments
article

Abstract 4143899: cusp-overlap view versus three cusp coplanar view during transcatheter aortic valve replacement using self-expandable valves: A meta-analysis of 5947 patients.

Serge Sicouri, Ahmed K. Awad, Ahmed R. Gonnah, Ramlawi Basel, Mohamed Ramadan, Basma Badrawy Khalefa, Ali Dway, Mazen Negmeldin Aly Yassin, Nada G. Hamam, Karim Alsalhi, Mazen Osman
article en

Abstract

Background & Objectives: Transcatheter aortic valve replacement (TAVR) is currently the treatment of choice for most patients with symptomatic severe aortic stenosis. We conducted this systematic review, and meta-analysis to compare the efficacy and procedural outcomes of using the cusp overlap technique (COT) versus the standard three-cusp technique during self-expandable valves implantation for the management of aortic stenosis. Methodology: We systematically searched PubMed, Scopus, Embase, Cochrane, and Web of Science (WOS) from inception to March 5, 2024, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. To estimate the effect size, dichotomous outcomes were pooled as risk ratio (RR), and continuous outcomes were pooled as mean difference (MD) with their respective 95% confidence interval (CI). Results: We included seventeen studies in our systematic review and meta-analysis with a total of 3129 patients in cusp-overlap technique (COT) arm and 2818 patients in standard technique (ST) arm. The rate of 30-day mortality was significantly decreased in COT compared with ST (RR = 0.61; 95% CI: [0.37–1.00], P = 0.05). Regarding conduction abnormalities, COT was related to lower risk of complete atrioventricular (AV) block (RR = 0.51; 95% CI: [0.37–0.69], P < 0.01), reduced likelihood of left bundle branch block (RR = 0.77; 95% CI: [0.61–0.97], P = 0.03) and permanent pacemaker implantation (PPI) (RR = 0.56; 95% CI: [0.46–0.70], P < 0.01). There was also lower likelihood of major and life-threatening bleeding with the COT compared to ST (RR = 0.60; 95% CI: [0.46–0.79], P < 0.01). Our analysis also showed that COT was associated with significantly lower implantation depth compared with ST (MD = -1.00; 95% Cl: [-1.83 to -0.17], P = 0.02). Procedural success was similar between COT and ST (RR = 1.01; 95% CI: [0.98–1.04], P = 0.42). Major vascular complications (RR = 0.90; 95% CI: [0.61–1.33], P = 0.61), and mild to severe paravalvular leak (RR = 1.00; 95% CI: [0.66–1.51], P = 1.00) were also comparable between COT and ST. Conclusion: Our study findings suggest that COT offers several advantages over ST, including reduced 30-day mortality and decreased bleeding complications, without compromising long-term outcomes or increasing procedural complications. The COT most importantly lower risk of conduction abnormalities, and hence permanent pacemaker implantation.

CirculationVol. 150(Suppl_1)
Ain Shams University (EG), Suez University (EG), Main Line Health (US), Cairo University (EG), Imperial College Healthcare NHS Trust (GB), Lankenau Institute for Medical Research (US), Lankenau Medical Center (US), King Abdulaziz Medical City (SA), Lankenau Heart Institute (US), Al Andalus University (SY), Batterjee Medical College
Good health and well-being
Openalex Percentile: Top 62%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.