Rapid and sensitive determination of bongkrekic acid with molecularly imprinted polymer-coated wooden-tip electrospray ionization mass spectrometry

In this study, a novel methodology has been developed for the rapid and sensitive analysis of bongkrekic acid (BA), a highly toxic bacterial metabolite, using a molecularly imprinted polymer-coated wooden-tip coupled with electrospray ionization mass spectrometry (MIPWT-ESI-MS). A MIPWT solid phase microextraction (SPME) probe specifically tailored for BA was fabricated, by employing dummy template molecules/functional monomers in the imprinting coating modification. This approach exhibits an enrichment factor (EF) of 683 ± 53 for efficient extraction of BA from aqueous matrices, demonstrating the utility of dummy templates in enhancing the selectivity and sensitivity of the MIPWT-ESI-MS method. The analytical performance of the MIPWT-ESI-MS method was evaluated, demonstrating a desirable linear correlation ( r = 0.9988), along with remarkable sensitivity by a limit of detection (LOD) and limit of quantitation (LOQ) at 0.05 μg/L and 0.16 μg/L in pure water, respectively. Additionally, the method demonstrated high repeatability with a relative standard deviation (RSD) < 3.9 % ( n = 6) and reproducibility with an RSD < 13.4 %. The practical application of the method was confirmed through the successful analysis of real-world samples, including tap water, wastewater from a food processing factory, and the aqueous extracts of food samples, with BA detected at 0.296 µg/L in Tremella . Spiking experiments further validated the accuracy of the method, with recoveries ranging from 81 % to 97 %. This study integrates MIP with ambient mass spectrometry, offering a robust, selective, and sensitive tool for the monitoring of trace BA levels in complex food and environmental samples, contributing significantly to public health safety and food quality control.

Authors

Institutions

Publication Details

Journal
Advances in Sample Preparation
Published
2024-10-01
DOI
https://doi.org/10.1016/j.sampre.2024.100137
Citations
3
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid and sensitive determination of bongkrekic acid with molecularly imprinted polymer-coated wooden-tip electrospray ionization mass spectrometry

Yunyun Yang, Jiewei Deng, Chunfei Zhong, Tiangang Luan et al.
3 citations
Advances in Sample Preparation
Analytical chemistry methods development
0.71
article

Rapid and sensitive determination of bongkrekic acid with molecularly imprinted polymer-coated wooden-tip electrospray ionization mass spectrometry

Yunyun Yang, Jiewei Deng, Chunfei Zhong, Tiangang Luan, Fan Zhang, Xinyan Li, Ning Liu
article en
3 citations

Abstract

In this study, a novel methodology has been developed for the rapid and sensitive analysis of bongkrekic acid (BA), a highly toxic bacterial metabolite, using a molecularly imprinted polymer-coated wooden-tip coupled with electrospray ionization mass spectrometry (MIPWT-ESI-MS). A MIPWT solid phase microextraction (SPME) probe specifically tailored for BA was fabricated, by employing dummy template molecules/functional monomers in the imprinting coating modification. This approach exhibits an enrichment factor (EF) of 683 ± 53 for efficient extraction of BA from aqueous matrices, demonstrating the utility of dummy templates in enhancing the selectivity and sensitivity of the MIPWT-ESI-MS method. The analytical performance of the MIPWT-ESI-MS method was evaluated, demonstrating a desirable linear correlation ( r = 0.9988), along with remarkable sensitivity by a limit of detection (LOD) and limit of quantitation (LOQ) at 0.05 μg/L and 0.16 μg/L in pure water, respectively. Additionally, the method demonstrated high repeatability with a relative standard deviation (RSD) < 3.9 % ( n = 6) and reproducibility with an RSD < 13.4 %. The practical application of the method was confirmed through the successful analysis of real-world samples, including tap water, wastewater from a food processing factory, and the aqueous extracts of food samples, with BA detected at 0.296 µg/L in Tremella . Spiking experiments further validated the accuracy of the method, with recoveries ranging from 81 % to 97 %. This study integrates MIP with ambient mass spectrometry, offering a robust, selective, and sensitive tool for the monitoring of trace BA levels in complex food and environmental samples, contributing significantly to public health safety and food quality control.

Advances in Sample PreparationVol. 12
Guangdong University of Technology (CN), Ji Hua Laboratory (CN), Guangdong Academy of Sciences (CN), Wuyi University (CN), Wuyi University (CN)
Openalex Percentile: Top 34%
Analytical chemistry methods development
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.