Multi-Angle Spectrophotometric Reflectance Methods for Determining Refractive Coefficients

The experience in developing and applying methods for measuring the refractive coefficients of high and middle category crystals based on multi-angle spectrophotometric reflectance methods (using the reflection spectrum from one face at a close-to-normal angle of incidence of light and the reflectance method where light falls at the Brewster angle) is peresented. Advantages and limitations of the methods and requirement to samples are described. It is shown that the reflectance method at a close-to-normal angle of incidence is applicable to optically isotropic media. The Brewster angle method is applicable to high and middle category crystals. The measurement accuracy is determined for both methods. Their applicability is verified for high- (Gd3Al2Ga3O12 : Ce) and middle category (La3Ga5.5Ta0.5O14) crystals.

Authors

Institutions

Publication Details

Journal
Crystallography Reports
Published
2024-10-01
DOI
https://doi.org/10.1134/s1063774524601746
Citations
2
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
1.32
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Angle Spectrophotometric Reflectance Methods for Determining Refractive Coefficients

V. M. Kasimova, Н. С. Козлова, Е. В. Забелина
2 citations
Crystallography Reports
Spectroscopy Techniques in Biomedical and Chemical Research
1.32
article

Multi-Angle Spectrophotometric Reflectance Methods for Determining Refractive Coefficients

V. M. Kasimova, Н. С. Козлова, Е. В. Забелина
article en
2 citations

Abstract

The experience in developing and applying methods for measuring the refractive coefficients of high and middle category crystals based on multi-angle spectrophotometric reflectance methods (using the reflection spectrum from one face at a close-to-normal angle of incidence of light and the reflectance method where light falls at the Brewster angle) is peresented. Advantages and limitations of the methods and requirement to samples are described. It is shown that the reflectance method at a close-to-normal angle of incidence is applicable to optically isotropic media. The Brewster angle method is applicable to high and middle category crystals. The measurement accuracy is determined for both methods. Their applicability is verified for high- (Gd3Al2Ga3O12 : Ce) and middle category (La3Ga5.5Ta0.5O14) crystals.

Crystallography ReportsVol. 69(5)
National University of Science and Technology (RU), National University of Science and Technology (ZW)
Climate action
Openalex Percentile: Top 14%
Spectroscopy Techniques in Biomedical and Chemical Research
1.32
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.