Evaluation of the Domino Effect Caused by Pool Fires in a Tank Farm

Major hazard installations (MHIs), such as oil refineries, petrochemical plants, and terminals, use large-capacity storage tanks for storing crude oil and by-products. Pool fire is one of the most common types of storage tank fire incidents. This technical article aims to investigate the domino effect resulting from a pool fire in a tank farm consisting of eight large floating-roof storage tanks, with a focus on four specific tanks. A crude oil storage tank was selected as the primary tank (source tank). Point source and plume solid models were used to estimate the thermal radiation. It has been noted that the thermal radiation from the source tank to the adjacent tank in the same dike exceeds the threshold heat radiation level and might result in a domino effect; however, the thermal radiation from the source tank alone does not reach the threshold level for the tanks in the other dike. Additionally, it was found that the thermal radiation from both the primary and secondary tanks just reaches the threshold level for the farther-away tank in the other dike. The domino effect occurs provided that the firefighting system is not activated and the emergency response team does not intervene within ten minutes.

Authors

Publication Details

Journal
Journal of Pure & Applied Sciences
Published
2024-11-13
DOI
https://doi.org/10.51984/jopas.v23i2.2998
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Domino Effect Caused by Pool Fires in a Tank Farm

Ibrahim Mohamed Shaluf, Salem A. Sakal, Nuha Krir
Journal of Pure & Applied Sciences
Fire dynamics and safety research
article

Evaluation of the Domino Effect Caused by Pool Fires in a Tank Farm

Ibrahim Mohamed Shaluf, Salem A. Sakal, Nuha Krir
article en

Abstract

Major hazard installations (MHIs), such as oil refineries, petrochemical plants, and terminals, use large-capacity storage tanks for storing crude oil and by-products. Pool fire is one of the most common types of storage tank fire incidents. This technical article aims to investigate the domino effect resulting from a pool fire in a tank farm consisting of eight large floating-roof storage tanks, with a focus on four specific tanks. A crude oil storage tank was selected as the primary tank (source tank). Point source and plume solid models were used to estimate the thermal radiation. It has been noted that the thermal radiation from the source tank to the adjacent tank in the same dike exceeds the threshold heat radiation level and might result in a domino effect; however, the thermal radiation from the source tank alone does not reach the threshold level for the tanks in the other dike. Additionally, it was found that the thermal radiation from both the primary and secondary tanks just reaches the threshold level for the farther-away tank in the other dike. The domino effect occurs provided that the firefighting system is not activated and the emergency response team does not intervene within ten minutes.

Journal of Pure & Applied SciencesVol. 23(2)
Openalex Percentile: Top 76%
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.