Abstract Su203: Development of Bioimpedance for the Measurement of Ventilation During Cardiopulmonary Resuscitation

Introduction: Previous studies have shown that ventilation during cardiopulmonary resuscitation (CPR) produces better patient outcomes. However, research regarding ventilation during the early stages of basic life support CPR is limited. Prior studies showed that thoracic bioimpedance, recorded by the LifePak 12 defibrillator device, can be used to count ventilations with a tidal volume at least 250 mL during CPR. However, the relationship between thoracic bioimpedance and tidal volume has yet to be studied for the Phillips MRx device, excluding a large data set from ventilation studies. Hypothesis: Bioimpedance, measured by the Phillips MRx device has a linear relationship with tidal volume. Aims: To determine the relationship between bioimpedance measured by the Phillips MRx device and tidal volume in males and females. Methods: We conducted the study in a respiratory laboratory at a University Hospital. We asked 27 volunteers to breathe fixed volumes (250 mL, 300 mL, 400 mL, 600 mL, and 800 mL) delivered by a mechanical ventilator while recording bioimpedance simultaneously with the Philips MRx monitor-defibrillator through electrode pads placed on the chest. Six measurements of bioimpedance waveform amplitudes (Ohms) were taken at each tidal volume. Results: Of 27 volunteers, 11 were female and 16 were male. In the female sample set, a linear equation of y=0.003x + 0.837 with an R^2 value of 0.9995 was calculated. In the male sample set, a linear equation of Y=0.0016x +0.1039 with a R^2 value of 0.995 was calculated. Females had a higher median bioimpedance amplitude than men at each tidal volume, and a steeper linear regression slope. At the minimum threshold tidal volume used for counting ventilations (250 mL), the median bioimpedance amplitude was 0.5 (0.4, 0.6) ohm for males and the median bioimpedance amplitude was 0.8 (0.6, 1) ohm for females. Conclusion: As measured and recorded with the Philips MRx monitor-defibrillator, there is a linear relationship between tidal volume and thoracic bioimpedance. The linear models created in this study can be used in future studies to count ventilations during CPR using the Philips MRx device.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.su203
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract Su203: Development of Bioimpedance for the Measurement of Ventilation During Cardiopulmonary Resuscitation

Paul Jarrett, Ahamed H. Idris, Ravi Prakash
Circulation
Hemodynamic Monitoring and Therapy
article

Abstract Su203: Development of Bioimpedance for the Measurement of Ventilation During Cardiopulmonary Resuscitation

Paul Jarrett, Ahamed H. Idris, Ravi Prakash
article en

Abstract

Introduction: Previous studies have shown that ventilation during cardiopulmonary resuscitation (CPR) produces better patient outcomes. However, research regarding ventilation during the early stages of basic life support CPR is limited. Prior studies showed that thoracic bioimpedance, recorded by the LifePak 12 defibrillator device, can be used to count ventilations with a tidal volume at least 250 mL during CPR. However, the relationship between thoracic bioimpedance and tidal volume has yet to be studied for the Phillips MRx device, excluding a large data set from ventilation studies. Hypothesis: Bioimpedance, measured by the Phillips MRx device has a linear relationship with tidal volume. Aims: To determine the relationship between bioimpedance measured by the Phillips MRx device and tidal volume in males and females. Methods: We conducted the study in a respiratory laboratory at a University Hospital. We asked 27 volunteers to breathe fixed volumes (250 mL, 300 mL, 400 mL, 600 mL, and 800 mL) delivered by a mechanical ventilator while recording bioimpedance simultaneously with the Philips MRx monitor-defibrillator through electrode pads placed on the chest. Six measurements of bioimpedance waveform amplitudes (Ohms) were taken at each tidal volume. Results: Of 27 volunteers, 11 were female and 16 were male. In the female sample set, a linear equation of y=0.003x + 0.837 with an R^2 value of 0.9995 was calculated. In the male sample set, a linear equation of Y=0.0016x +0.1039 with a R^2 value of 0.995 was calculated. Females had a higher median bioimpedance amplitude than men at each tidal volume, and a steeper linear regression slope. At the minimum threshold tidal volume used for counting ventilations (250 mL), the median bioimpedance amplitude was 0.5 (0.4, 0.6) ohm for males and the median bioimpedance amplitude was 0.8 (0.6, 1) ohm for females. Conclusion: As measured and recorded with the Philips MRx monitor-defibrillator, there is a linear relationship between tidal volume and thoracic bioimpedance. The linear models created in this study can be used in future studies to count ventilations during CPR using the Philips MRx device.

CirculationVol. 150(Suppl_1)
Southwestern Medical Center (US), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 61%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.