Abstract Su507: Occurrence of Fibrillation in Out-of-hospital Cardiac Arrest Patients Presenting in a Non-shockable Rhythm when Treated with an Automated External Defibrillator

Background: Most out-of-hospital cardiac arrest (OHCA) patients who are initially treated with an automated external defibrillator (AED) and present in a non-shockable rhythm never receive a shock. This analysis reports on patients who presented in a non-shockable rhythm when the AED was initially applied and later transitioned into a shockable rhythm. Methods: Data from a convenience group of OHCA patients treated with a Philips HeartStart Home, Onsite or FRx AED were included. The AEDs were the first defibrillator on scene either in home, in public access or by a BLS team. Application of any medication during AED use was unlikely. Each patient’s heart rhythms were reviewed by an expert. All patients whose initial rhythm was non-shockable but later received at least one shock were identified and the rhythms were analyzed. Results: Out of 876 patients, 322 (36.8%) received at least one shock, of which five patients (1.6%) presented in a non-shockable rhythm and were later shocked. Three patients presented in an organized rhythm. The first patient degraded into Torsade de Pointe as shown in Figure 1; the post-shock rhythm was organized. The second patient received no CPR and A-V pacing was observed in the ECG recording. The pacing stopped when the rhythm transitioned into VF and restarted post shock. The third patient transitioned into VF during chest compressions and the post-shock rhythm was asystole. The remaining two patients presented in asystole and the rhythm evolved to fine VF after receiving chest compressions. After defibrillation, their rhythms returned to asystole. Conclusions: For OHCA patients treated with an AED, presenting in a non-shockable rhythm and later transitioning into a shockable rhythm is rare but possible. Lay-responder CPR may play a role in rhythm evolvement. The impact of rhythm changes on survivability of these patients is unknown.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.su507
Primary Topic
Cardiac Arrest and Resuscitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract Su507: Occurrence of Fibrillation in Out-of-hospital Cardiac Arrest Patients Presenting in a Non-shockable Rhythm when Treated with an Automated External Defibrillator

Stacy Gehman, Dawn Jorgenson, Mengqi Gao, Chenguang Liu
Circulation
Cardiac Arrest and Resuscitation
article

Abstract Su507: Occurrence of Fibrillation in Out-of-hospital Cardiac Arrest Patients Presenting in a Non-shockable Rhythm when Treated with an Automated External Defibrillator

Stacy Gehman, Dawn Jorgenson, Mengqi Gao, Chenguang Liu
article en

Abstract

Background: Most out-of-hospital cardiac arrest (OHCA) patients who are initially treated with an automated external defibrillator (AED) and present in a non-shockable rhythm never receive a shock. This analysis reports on patients who presented in a non-shockable rhythm when the AED was initially applied and later transitioned into a shockable rhythm. Methods: Data from a convenience group of OHCA patients treated with a Philips HeartStart Home, Onsite or FRx AED were included. The AEDs were the first defibrillator on scene either in home, in public access or by a BLS team. Application of any medication during AED use was unlikely. Each patient’s heart rhythms were reviewed by an expert. All patients whose initial rhythm was non-shockable but later received at least one shock were identified and the rhythms were analyzed. Results: Out of 876 patients, 322 (36.8%) received at least one shock, of which five patients (1.6%) presented in a non-shockable rhythm and were later shocked. Three patients presented in an organized rhythm. The first patient degraded into Torsade de Pointe as shown in Figure 1; the post-shock rhythm was organized. The second patient received no CPR and A-V pacing was observed in the ECG recording. The pacing stopped when the rhythm transitioned into VF and restarted post shock. The third patient transitioned into VF during chest compressions and the post-shock rhythm was asystole. The remaining two patients presented in asystole and the rhythm evolved to fine VF after receiving chest compressions. After defibrillation, their rhythms returned to asystole. Conclusions: For OHCA patients treated with an AED, presenting in a non-shockable rhythm and later transitioning into a shockable rhythm is rare but possible. Lay-responder CPR may play a role in rhythm evolvement. The impact of rhythm changes on survivability of these patients is unknown.

CirculationVol. 150(Suppl_1)
Philips (United States) (US)
Good health and well-being
Openalex Percentile: Top 64%
Cardiac Arrest and Resuscitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Abstract Su507: Occurrence of Fibrillation in Out-of-hospital Cardiac Arrest Patients Presenting in a Non-shockable Rhythm when Treated with an Automated External Defibrillator — Stacy Gehman, Dawn Jorgenson, et al. · Circulation (2024) | TGRS Research Map | TGRS