Enhancing time-resolution for radon measurements using airflow-through scintillation cells based on a compartmental model approach

To overcome the time-resolution limitation inherent in the airflow-through scintillation cell method for radon measurement, this study introduces a compartmental model elucidating the behaviors of radon and its progeny within such cells. The computed results of the normalized equilibrium functions derived from the compartmental model, provide quantitative insights into the equilibrium progression of 222Rn and its progeny over time, substantiating the identified time-resolution limitation of 2-3 hours. Laboratory experiments confirm the efficacy of the proposed correction algorithm, showcasing its ability to surmount the time-resolution limitation and achieve a rapid response in radon measurement using airflow-through scintillation cells.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-11-01
DOI
https://doi.org/10.1093/rpd/ncae062
Citations
1
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.45

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing time-resolution for radon measurements using airflow-through scintillation cells based on a compartmental model approach

Yanliang Chen, Chaoyong Hu, Chao Zhao, Gang Han et al.
1 citations
Radiation Protection Dosimetry
Radioactivity and Radon Measurements
0.45
article

Enhancing time-resolution for radon measurements using airflow-through scintillation cells based on a compartmental model approach

Yanliang Chen, Chaoyong Hu, Chao Zhao, Gang Han, Linfeng He, Jiayu Liu, Fangdong Tang
article en
1 citations

Abstract

To overcome the time-resolution limitation inherent in the airflow-through scintillation cell method for radon measurement, this study introduces a compartmental model elucidating the behaviors of radon and its progeny within such cells. The computed results of the normalized equilibrium functions derived from the compartmental model, provide quantitative insights into the equilibrium progression of 222Rn and its progeny over time, substantiating the identified time-resolution limitation of 2-3 hours. Laboratory experiments confirm the efficacy of the proposed correction algorithm, showcasing its ability to surmount the time-resolution limitation and achieve a rapid response in radon measurement using airflow-through scintillation cells.

Radiation Protection DosimetryVol. 200(16-18)
Shanghai Institute of Measurement and Testing Technology (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 34%
Radioactivity and Radon Measurements
0.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.