Assessment of annual effective doses from indoor radon and thoron in Doi Lo, Chiang Mai, Thailand

This study aimed to determine the annual effective dose resulting from radon and thoron progeny inhalation. The levels of radon, thoron, and progeny were assessed in residences situated in the Doi Lo region of Chiang Mai, Thailand. Indoor radon and thoron concentrations were detected using passive discriminative detectors. Using a progeny deposition rate detector, this study evaluates radon and thoron progeny [equilibrium-equivalent radon concentration (EERC) for radon and equilibrium-equivalent thoron concentration (EETC) for thoron]. Data were collected from 44 dwellings between March and May 2020. The results found that indoor radon concentrations ranged from 17 to 118 Bq m-3, while thoron concentrations ranged from 12 to 72 Bq m-3. The radon progeny (EERC) ranged from 4 to 173 Bq m-3, whereas thoron progeny (EETC) ranged from 1 to 15 Bq m-3. The total annual effective dose received from radon and thoron progeny inhalation varied from 0.5 to 5 mSv y-1.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2024-11-01
DOI
https://doi.org/10.1093/rpd/ncae130
Citations
1
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.45
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of annual effective doses from indoor radon and thoron in Doi Lo, Chiang Mai, Thailand

Shinji Tokonami, Monruedee Tapanya, Supitcha Chanyotha, Chutima Kranrod et al.
1 citations
Radiation Protection Dosimetry
Radioactivity and Radon Measurements
0.45
article

Assessment of annual effective doses from indoor radon and thoron in Doi Lo, Chiang Mai, Thailand

Shinji Tokonami, Monruedee Tapanya, Supitcha Chanyotha, Chutima Kranrod, Tarika Thumvijit, Sompong Sriburee, Siriprapa Somboon, Kewalin Ruktinnakorn
article en
1 citations

Abstract

This study aimed to determine the annual effective dose resulting from radon and thoron progeny inhalation. The levels of radon, thoron, and progeny were assessed in residences situated in the Doi Lo region of Chiang Mai, Thailand. Indoor radon and thoron concentrations were detected using passive discriminative detectors. Using a progeny deposition rate detector, this study evaluates radon and thoron progeny [equilibrium-equivalent radon concentration (EERC) for radon and equilibrium-equivalent thoron concentration (EETC) for thoron]. Data were collected from 44 dwellings between March and May 2020. The results found that indoor radon concentrations ranged from 17 to 118 Bq m-3, while thoron concentrations ranged from 12 to 72 Bq m-3. The radon progeny (EERC) ranged from 4 to 173 Bq m-3, whereas thoron progeny (EETC) ranged from 1 to 15 Bq m-3. The total annual effective dose received from radon and thoron progeny inhalation varied from 0.5 to 5 mSv y-1.

Radiation Protection DosimetryVol. 200(16-18)
Hirosaki University (JP), Chulalongkorn University (TH), Chiang Mai University (TH)
Reduced inequalities
Openalex Percentile: Top 34%
Radioactivity and Radon Measurements
0.45
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.