Abstract 4138310: Successful Endovascular Closure of Ascending Aortic Pseudoaneurysm Using Atrial Septal Defect Occluder

Introduction: Ascending aortic pseudoaneurysms are mostly related to either surgery or non-surgical trauma. Any pseudoaneurysm arising from graft anastomoses, regardless of size or location, must be repaired due to the potential for catastrophic rupture. Traditional surgical intervention has a high mortality rate, but percutaneous treatment has emerged as an alternative. We present such a case of pseudoaneurysm treated by percutaneous intervention using a 6-mm Amplatzer device. Case: A 77-year-old female with a history of type A aortic dissection s/p emergent repair with a 32 mm tube graft one year ago presented with chest pain radiating to her back. Initial vital signs showed a BP of 185/105, SaO2 98% on RA, 98.3 F, HR 98 bpm, and RR 24/min. A chest CT scan suggested a pseudoaneurysm at the proximal anastomotic site of the aortic graft (Figs. 1A and B). Serial troponin and EKGs were unremarkable for acute ischemia. Multiple quaternary centers declined intervention due to the high risk of redo sternotomy for open repair and patient frailty. After multidisciplinary discussions, it was felt that percutaneous closure with an Amplatzer device was possible without coronary obstruction. In the catheterization lab, a TEE probe was placed to visualize the pseudoaneurysm of the ascending aorta (Fig. 1C). Angiography showed the aneurysm coming off the posterior aorta just above the noncoronary cusp, with the neck measuring ~6 mm (Fig. 1D). The aneurysm was successfully engaged using an 8-French sheath and an 8-French AL1. Based on measurements from the TEE and the angiogram, a 6 mm ASO device was used. After device deployment and release, aortograms showed that the pseudoaneurysm was excluded (Fig. 1H). Assessment with TEE and CTA showed no residual flow in the pseudoaneurysm (Fig. 1 E–G). Conclusion: Using an atrial septal occluder, endovascular intervention may be a safe and effective alternative to surgery for treating the ascending aortic pseudoaneurysm, especially in patients with a high prohibitive surgical risk. Longitudinal follow-ups are needed to comment on long-term mortality benefits for these individuals.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4138310
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4138310: Successful Endovascular Closure of Ascending Aortic Pseudoaneurysm Using Atrial Septal Defect Occluder

John F. Wagener, Muhammad Asif, Michael Bacharach, Wahab J Khan et al.
Circulation
Cardiovascular and Diving-Related Complications
article

Abstract 4138310: Successful Endovascular Closure of Ascending Aortic Pseudoaneurysm Using Atrial Septal Defect Occluder

John F. Wagener, Muhammad Asif, Michael Bacharach, Wahab J Khan, Christopher Paa
article en

Abstract

Introduction: Ascending aortic pseudoaneurysms are mostly related to either surgery or non-surgical trauma. Any pseudoaneurysm arising from graft anastomoses, regardless of size or location, must be repaired due to the potential for catastrophic rupture. Traditional surgical intervention has a high mortality rate, but percutaneous treatment has emerged as an alternative. We present such a case of pseudoaneurysm treated by percutaneous intervention using a 6-mm Amplatzer device. Case: A 77-year-old female with a history of type A aortic dissection s/p emergent repair with a 32 mm tube graft one year ago presented with chest pain radiating to her back. Initial vital signs showed a BP of 185/105, SaO2 98% on RA, 98.3 F, HR 98 bpm, and RR 24/min. A chest CT scan suggested a pseudoaneurysm at the proximal anastomotic site of the aortic graft (Figs. 1A and B). Serial troponin and EKGs were unremarkable for acute ischemia. Multiple quaternary centers declined intervention due to the high risk of redo sternotomy for open repair and patient frailty. After multidisciplinary discussions, it was felt that percutaneous closure with an Amplatzer device was possible without coronary obstruction. In the catheterization lab, a TEE probe was placed to visualize the pseudoaneurysm of the ascending aorta (Fig. 1C). Angiography showed the aneurysm coming off the posterior aorta just above the noncoronary cusp, with the neck measuring ~6 mm (Fig. 1D). The aneurysm was successfully engaged using an 8-French sheath and an 8-French AL1. Based on measurements from the TEE and the angiogram, a 6 mm ASO device was used. After device deployment and release, aortograms showed that the pseudoaneurysm was excluded (Fig. 1H). Assessment with TEE and CTA showed no residual flow in the pseudoaneurysm (Fig. 1 E–G). Conclusion: Using an atrial septal occluder, endovascular intervention may be a safe and effective alternative to surgery for treating the ascending aortic pseudoaneurysm, especially in patients with a high prohibitive surgical risk. Longitudinal follow-ups are needed to comment on long-term mortality benefits for these individuals.

CirculationVol. 150(Suppl_1)
Avera McKennan Hospital & University Health Center (US), North Central College (US)
Good health and well-being
Openalex Percentile: Top 61%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.