Abstract 4138564: Fitbit-Measured Physical Activity Is Inversely Associated With Incident Atrial Fibrillation Among All Of Us Participants

Background: Studies show that moderate to vigorous physical activity (MVPA) reduces atrial fibrillation (AF) risk. However, these studies used subjective questionnaires or short-term (<1 week) accelerometry assessments. Objective: This study investigated the link between MVPA levels and AF incidence using long-term (1-year) accelerometry data from the NIH All of Us Fitbit database. Methods: The study included All of Us participants who agreed to share electronic health record (EHR) and Fitbit data between January 1, 2016 to July 1, 2022. Among participants without an existing diagnosis of AF, the average weekly minutes of MVPA over the first year of Fitbit use was computed. Incident AF events were identified using validated ICD-10 codes in a five-year follow-up period. The risk of incident AF was evaluated using Cox proportional hazards regression models, for both MVPA as a continuous and a categorical variable (<30, 30-150,151-300, and >300 minutes MVPA per week; aligned with WHO guidelines). Covariates included age, sex, race/ethnicity, BMI, smoking status, and diagnoses of hypertension and diabetes. In a subset of participants with whole genome data, we evaluated if the association between MVPA and AF incidence varied by a participant’s AF genetic risk score (GRS) Results: 6086 participants (mean age 50 years, 71% female, 83% White) had EHR and at least 1 year of Fitbit data. Over the 1-year MVPA assessment period, participants had 41±12 weeks of complete data and a median 202 [241] minutes of MVPA per week. 55 participants (0.9%) experienced incident AF in the five-year follow-up period. In adjusted analysis, every additional hour of MVPA was associated with an 11% reduced risk of AF (HR = 0.89 [0.81,0.98], p = 0.02). There was a step-wise reduction in risk of AF by MVPA category with <30 min/week as the reference: 30-150 (HR = 0.62 [0.24,1.6], p = 0.31), 151-300 (HR = 0.40 [0.15,1.07], p = 0.07), and >300 (HR = 0.35 [0.13,0.95], p = 0.04) ( Figure 1 ). These associations also held after adjusting for GRS. Conclusion: Higher amounts of objectively measured MVPA were inversely associated with risk of incident AF, independent of clinical and genetic risk factors.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2024-11-12
DOI
https://doi.org/10.1161/circ.150.suppl_1.4138564
Primary Topic
Cardiac Health and Mental Health
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4138564: Fitbit-Measured Physical Activity Is Inversely Associated With Incident Atrial Fibrillation Among All Of Us Participants

D. Upadhyay, Souptik Barua, Morgan E. Grams, Aditya Surapaneni et al.
Circulation
Cardiac Health and Mental Health
article

Abstract 4138564: Fitbit-Measured Physical Activity Is Inversely Associated With Incident Atrial Fibrillation Among All Of Us Participants

D. Upadhyay, Souptik Barua, Morgan E. Grams, Aditya Surapaneni, Sean Heffron
article en

Abstract

Background: Studies show that moderate to vigorous physical activity (MVPA) reduces atrial fibrillation (AF) risk. However, these studies used subjective questionnaires or short-term (<1 week) accelerometry assessments. Objective: This study investigated the link between MVPA levels and AF incidence using long-term (1-year) accelerometry data from the NIH All of Us Fitbit database. Methods: The study included All of Us participants who agreed to share electronic health record (EHR) and Fitbit data between January 1, 2016 to July 1, 2022. Among participants without an existing diagnosis of AF, the average weekly minutes of MVPA over the first year of Fitbit use was computed. Incident AF events were identified using validated ICD-10 codes in a five-year follow-up period. The risk of incident AF was evaluated using Cox proportional hazards regression models, for both MVPA as a continuous and a categorical variable (<30, 30-150,151-300, and >300 minutes MVPA per week; aligned with WHO guidelines). Covariates included age, sex, race/ethnicity, BMI, smoking status, and diagnoses of hypertension and diabetes. In a subset of participants with whole genome data, we evaluated if the association between MVPA and AF incidence varied by a participant’s AF genetic risk score (GRS) Results: 6086 participants (mean age 50 years, 71% female, 83% White) had EHR and at least 1 year of Fitbit data. Over the 1-year MVPA assessment period, participants had 41±12 weeks of complete data and a median 202 [241] minutes of MVPA per week. 55 participants (0.9%) experienced incident AF in the five-year follow-up period. In adjusted analysis, every additional hour of MVPA was associated with an 11% reduced risk of AF (HR = 0.89 [0.81,0.98], p = 0.02). There was a step-wise reduction in risk of AF by MVPA category with <30 min/week as the reference: 30-150 (HR = 0.62 [0.24,1.6], p = 0.31), 151-300 (HR = 0.40 [0.15,1.07], p = 0.07), and >300 (HR = 0.35 [0.13,0.95], p = 0.04) ( Figure 1 ). These associations also held after adjusting for GRS. Conclusion: Higher amounts of objectively measured MVPA were inversely associated with risk of incident AF, independent of clinical and genetic risk factors.

CirculationVol. 150(Suppl_1)
New York University (US)
Good health and well-being
Openalex Percentile: Top 63%
Cardiac Health and Mental Health
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.