Layer-by-layer self-assembled poly(diallyldimethylammonium chloride)/cyclodextrin composite materials for the electrochemical detection of paracetamol

This study reports the development of a sensitive electrochemical sensor for paracetamol detection based on a layer-by-layer self-assembled poly(diallyl dimethylammonium chloride)/β-cyclodextrin (PDDA/β-CD) composite film. The optimized 5-bilayer PDDA/β-CD modified glassy carbon electrode exhibited enhanced electron transfer kinetics and analyte preconcentration. Scanning electron microscopy revealed a porous, three-dimensional network structure, while X-ray photoelectron spectroscopy confirmed the successful incorporation of both PDDA and β-CD components. Electrochemical impedance spectroscopy showed a minimum charge transfer resistance of 119 Ω for the 1-bilayer modified electrode. The sensor showed two distinct linear response intervals (0.01–50 μM and 50–500 μM) and was able to detect concentrations as low as 0.03 μM. The investigation into pH dependence suggested that paracetamol oxidation follows a two-electron, two-proton mechanism, with the best results observed at pH 7.0. The modified electrode showed excellent selectivity, maintaining its response in the presence of common interferents at 10-fold excess concentrations. The sensor showed consistent results (relative standard deviation (RSD) = 3.2 %, n = 5) and remained stable over time, maintaining 92 % of its original performance after a month. Practical applicability was demonstrated through accurate paracetamol determination in pharmaceutical formulations (recoveries 98.6–101.2 %) and spiked urine samples (recoveries 97.8–102.5 %). The proposed PDDA/β-CD composite sensor offers a simple, cost-effective, and environmentally friendly platform for paracetamol analysis in pharmaceutical and practical applications.

Authors

Institutions

Publication Details

Journal
International Journal of Electrochemical Science
Published
2024-11-13
DOI
https://doi.org/10.1016/j.ijoes.2024.100878
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Layer-by-layer self-assembled poly(diallyldimethylammonium chloride)/cyclodextrin composite materials for the electrochemical detection of paracetamol

Yuqiong Liu, Haiyan Yan, Haochang Guo, Yuqi Liu et al.
4 citations
International Journal of Electrochemical Science
Electrochemical sensors and biosensors
0.83
article

Layer-by-layer self-assembled poly(diallyldimethylammonium chloride)/cyclodextrin composite materials for the electrochemical detection of paracetamol

Yuqiong Liu, Haiyan Yan, Haochang Guo, Yuqi Liu, Zhen‐Guo Liu, Mengjia Zhao, Ruirui Yang
article en
4 citations

Abstract

This study reports the development of a sensitive electrochemical sensor for paracetamol detection based on a layer-by-layer self-assembled poly(diallyl dimethylammonium chloride)/β-cyclodextrin (PDDA/β-CD) composite film. The optimized 5-bilayer PDDA/β-CD modified glassy carbon electrode exhibited enhanced electron transfer kinetics and analyte preconcentration. Scanning electron microscopy revealed a porous, three-dimensional network structure, while X-ray photoelectron spectroscopy confirmed the successful incorporation of both PDDA and β-CD components. Electrochemical impedance spectroscopy showed a minimum charge transfer resistance of 119 Ω for the 1-bilayer modified electrode. The sensor showed two distinct linear response intervals (0.01–50 μM and 50–500 μM) and was able to detect concentrations as low as 0.03 μM. The investigation into pH dependence suggested that paracetamol oxidation follows a two-electron, two-proton mechanism, with the best results observed at pH 7.0. The modified electrode showed excellent selectivity, maintaining its response in the presence of common interferents at 10-fold excess concentrations. The sensor showed consistent results (relative standard deviation (RSD) = 3.2 %, n = 5) and remained stable over time, maintaining 92 % of its original performance after a month. Practical applicability was demonstrated through accurate paracetamol determination in pharmaceutical formulations (recoveries 98.6–101.2 %) and spiked urine samples (recoveries 97.8–102.5 %). The proposed PDDA/β-CD composite sensor offers a simple, cost-effective, and environmentally friendly platform for paracetamol analysis in pharmaceutical and practical applications.

International Journal of Electrochemical ScienceVol. 19(12)
Henan University (CN), Xi'an Technological University (CN), Luoyang Cement Engineering Design and Research Institute (CN), Luoyang Institute of Science and Technology (CN)
Openalex Percentile: Top 26%
Electrochemical sensors and biosensors
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.