Assessment of Oil Paints for Corrosion Protection of Reinforcing Steel Bars in Concrete

Corrosion becomes a threat to reinforced concrete structural integrity during the service life of the structural member. This situation has become a global concern because of the economic and safety implications. Hence, many corrosion inhibition techniques including coating with materials (organic and inorganic) were used to prevent its devastating effects. The present study used three oil paint brands (mat, red-oxide and gloss Leyland oil paints in Ghana) to variedly coat reinforcing steel bars to ascertain their corrosion protection capacity in concrete. There were zero, one, two and three paint coats of average film thickness, 72 µm, 129 µm and 220 µm respectively explored. An Electrochemical process involved simulated concrete pore solution made of 10% sodium chloride (NaCl) in distilled water with three electrode systems to represent a corrosion medium was used to determine corrosion protection capacity of the paints. The results indicate over 90% corrosion resistance of the paints used. Comparing the corrosion rates of the coated and uncoated reinforcing steel bars, while it would take a one coat steel bar 342.5 years and 237 years respectively for spraying and manual brushing modes to reduce in diameter by 0.616mm, it would take only one year for an uncoated steel bar to reduce by this same 0.616mm. The protection capacity proved better with increasing coats on all corrosion variables for the selected paints used. The implication is that the selected oil paint brands are capable of protecting reinforcing steel bars in concrete against corrosion and therefore recommended for application to reduce maintenance cost. Statistically, no significant difference existed between coating mode, number of coatings, paint type and steel type on the corrosion variables for the coated steel bars. However, a further study about the durability of the coating in the concrete during its service time is recommended.

Authors

Institutions

Publication Details

Journal
Journal of Scientific Research and Reports
Published
2024-11-13
DOI
https://doi.org/10.9734/jsrr/2024/v30i112598
Citations
1
Primary Topic
Concrete Corrosion and Durability
Type
article
Field-Weighted Citation Impact
0.26
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Oil Paints for Corrosion Protection of Reinforcing Steel Bars in Concrete

Jack Banahene Osei, Evans Biney, Vincent K. Akortia, Charles K. Kankam et al.
1 citations
Journal of Scientific Research and Reports
Concrete Corrosion and Durability
0.26
article

Assessment of Oil Paints for Corrosion Protection of Reinforcing Steel Bars in Concrete

Jack Banahene Osei, Evans Biney, Vincent K. Akortia, Charles K. Kankam, Perseverance Dzikunu, Russel O. Afrifa
article en
1 citations

Abstract

Corrosion becomes a threat to reinforced concrete structural integrity during the service life of the structural member. This situation has become a global concern because of the economic and safety implications. Hence, many corrosion inhibition techniques including coating with materials (organic and inorganic) were used to prevent its devastating effects. The present study used three oil paint brands (mat, red-oxide and gloss Leyland oil paints in Ghana) to variedly coat reinforcing steel bars to ascertain their corrosion protection capacity in concrete. There were zero, one, two and three paint coats of average film thickness, 72 µm, 129 µm and 220 µm respectively explored. An Electrochemical process involved simulated concrete pore solution made of 10% sodium chloride (NaCl) in distilled water with three electrode systems to represent a corrosion medium was used to determine corrosion protection capacity of the paints. The results indicate over 90% corrosion resistance of the paints used. Comparing the corrosion rates of the coated and uncoated reinforcing steel bars, while it would take a one coat steel bar 342.5 years and 237 years respectively for spraying and manual brushing modes to reduce in diameter by 0.616mm, it would take only one year for an uncoated steel bar to reduce by this same 0.616mm. The protection capacity proved better with increasing coats on all corrosion variables for the selected paints used. The implication is that the selected oil paint brands are capable of protecting reinforcing steel bars in concrete against corrosion and therefore recommended for application to reduce maintenance cost. Statistically, no significant difference existed between coating mode, number of coatings, paint type and steel type on the corrosion variables for the coated steel bars. However, a further study about the durability of the coating in the concrete during its service time is recommended.

Journal of Scientific Research and ReportsVol. 30(11)
Ho Technical University (GH), Kwame Nkrumah University of Science and Technology (GH)
Openalex Percentile: Top 43%
Concrete Corrosion and Durability
0.26
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.