Drinking water buffer intensity simulator (<scp>BIS</scp>): Development and practical simulations

Abstract An established body of research over many decades has identified the importance of both bulk‐water and pipe scale surface microenvironment buffering to meet distribution system pH targets and reduce corrosivity toward metallic piping and components. Buffer intensity quantifies the ability of water to resist pH changes, and the greater the buffer intensity, the more resistant the water is to pH changes. To provide a practical tool for exploring buffer intensity, a buffer intensity simulator (BIS) was implemented in open‐source R code, incorporating typical chemical species (e.g., carbonate and orthophosphate) that contribute to drinking water buffer intensity along with temperature and ionic strength impacts. The BIS was verified against a parallel spreadsheet implementation and is publicly available at https://github.com/USEPA/BIS . Simulations were conducted to illustrate impacts related to buffer intensity using three practical scenarios: carbonate buffering in drinking waters, temperature impacts, and free ammonia presence from chloramine use and/or source water presence.

Authors

Institutions

Publication Details

Journal
AWWA Water Science
Published
2024-11-01
DOI
https://doi.org/10.1002/aws2.70006
Primary Topic
Environmental and Analytical Chemistry Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Drinking water buffer intensity simulator (BIS): Development and practical simulations

Michael R. Schock, Darren A. Lytle, David G. Wahman
AWWA Water Science
Environmental and Analytical Chemistry Studies
article

Drinking water buffer intensity simulator (BIS): Development and practical simulations

Michael R. Schock, Darren A. Lytle, David G. Wahman
article en

Abstract

Abstract An established body of research over many decades has identified the importance of both bulk‐water and pipe scale surface microenvironment buffering to meet distribution system pH targets and reduce corrosivity toward metallic piping and components. Buffer intensity quantifies the ability of water to resist pH changes, and the greater the buffer intensity, the more resistant the water is to pH changes. To provide a practical tool for exploring buffer intensity, a buffer intensity simulator (BIS) was implemented in open‐source R code, incorporating typical chemical species (e.g., carbonate and orthophosphate) that contribute to drinking water buffer intensity along with temperature and ionic strength impacts. The BIS was verified against a parallel spreadsheet implementation and is publicly available at https://github.com/USEPA/BIS . Simulations were conducted to illustrate impacts related to buffer intensity using three practical scenarios: carbonate buffering in drinking waters, temperature impacts, and free ammonia presence from chloramine use and/or source water presence.

AWWA Water ScienceVol. 6(6)
Environmental Protection Agency (US), Ohio Environmental Protection Agency (US)
Clean water and sanitation
Openalex Percentile: Top 80%
Environmental and Analytical Chemistry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.