A modified human shoulder model considering the migration of the humeral head from the scapular glenoid fossa for the design of shoulder exoskeletons

The wearable upper limb exoskeletons designed using the traditional shoulder model have a serious issue related to joint axis misalignment with the human shoulder. The misalignment is primarily due to the limited degrees of freedom model assumed for the shoulder. The glenohumeral joint in the conventional upper limb model is considered a single spherical joint, which, when considering the human anatomy, neglects the humeral head translation from the glenoid fossa of the scapula. This shoulder model cannot be used for designing the wearable upper limb exoskeletons, which can damage the shoulder joint due to interactive forces generated from the human-exoskeleton joint misalignment. This paper presents a modified, anatomically similar, human upper limb model where the single spherical joint of the glenohumeral joint is modified into two spherical joints connected by a prismatic joint. The kinematic and dynamic model of the proposed shoulder model is explained in detail. The elbow reachable space for this model has been calculated and compared with that of the existing models, and it is found to be closer to the actual workspace. The proposed model is simulated with a conventional exoskeleton attachment to show the effect of misalignment during humeral head translation and the benefits of using the proposed model in the design of the shoulder exoskeleton. An exoskeleton test bench that uses the modified shoulder model is also presented.

Authors

Institutions

Publication Details

Journal
Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science
Published
2024-11-12
DOI
https://doi.org/10.1177/09544062241295631
Citations
3
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
1.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A modified human shoulder model considering the migration of the humeral head from the scapular glenoid fossa for the design of shoulder exoskeletons

Santhakumar Mohan, Avinash S Pramod, Asokan Thondiyath
3 citations
Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science
Shoulder Injury and Treatment
1.72
article

A modified human shoulder model considering the migration of the humeral head from the scapular glenoid fossa for the design of shoulder exoskeletons

Santhakumar Mohan, Avinash S Pramod, Asokan Thondiyath
article en
3 citations

Abstract

The wearable upper limb exoskeletons designed using the traditional shoulder model have a serious issue related to joint axis misalignment with the human shoulder. The misalignment is primarily due to the limited degrees of freedom model assumed for the shoulder. The glenohumeral joint in the conventional upper limb model is considered a single spherical joint, which, when considering the human anatomy, neglects the humeral head translation from the glenoid fossa of the scapula. This shoulder model cannot be used for designing the wearable upper limb exoskeletons, which can damage the shoulder joint due to interactive forces generated from the human-exoskeleton joint misalignment. This paper presents a modified, anatomically similar, human upper limb model where the single spherical joint of the glenohumeral joint is modified into two spherical joints connected by a prismatic joint. The kinematic and dynamic model of the proposed shoulder model is explained in detail. The elbow reachable space for this model has been calculated and compared with that of the existing models, and it is found to be closer to the actual workspace. The proposed model is simulated with a conventional exoskeleton attachment to show the effect of misalignment during humeral head translation and the benefits of using the proposed model in the design of the shoulder exoskeleton. An exoskeleton test bench that uses the modified shoulder model is also presented.

Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering ScienceVol. 239(5)
Indian Institute of Technology Madras (IN), Indian Institute of Technology Palakkad (IN)
Peace, Justice and strong institutions
Openalex Percentile: Top 14%
Shoulder Injury and Treatment
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.