Review of the <scp>NRC</scp> Canada studies on fire resistance of floor assemblies: Results, design guidelines and research gaps

Abstract The National Research Council Canada conducted two major fire resistance studies on floor assemblies over the past two decades. Despite the publication of the experimental results, there is a lack of suggested guidelines for design practitioners and gaps for future research. Thus, this paper comprehensively reviews the fire resistance results of 85 full‐scale floor tests, suggests design guidelines, and identifies research gaps. These efforts aim to enhance the understanding and support the potential improvement of the fire performance of floor assemblies. The review of the results covers the impact of various design parameters on the fire resistance of floor assemblies, such as framing type and spacing, insulation type, subfloor configuration, resilient channel spacing, number of gypsum board layers, and screw spacing from the board edge. Although the interaction of these factors is complex, some of them play significant roles in determining the overall fire resistance of floor assemblies. For instance, rock and cellulose insulation outperformed glass fibre, a wider resilient channel spacing lowered fire resistance, whilst an increased distance of screws from the board edge improved the fire resistance. More importantly, detailed explanations are provided for the influences these parameters exert on fire resistance. Following this detailed examination of the results, design guidelines are provided for practitioners' consideration. A comparison is made between the experimental results and predictions from the component additive methods in the Canadian and Euro Codes, demonstrating that both methods yield conservative results. Finally, this paper concludes by identifying research gaps and providing recommendations for future investigations, including the necessity of experimental studies on floor assemblies with new design configurations and the promising role of machine learning in fire resistance evaluation.

Authors

Institutions

Publication Details

Journal
Fire and Materials
Published
2024-11-13
DOI
https://doi.org/10.1002/fam.3244
Citations
2
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Review of the NRC Canada studies on fire resistance of floor assemblies: Results, design guidelines and research gaps

Linbo Zhang, Mohamed A. Sultan
2 citations
Fire and Materials
Fire effects on concrete materials
0.52
article

Review of the NRC Canada studies on fire resistance of floor assemblies: Results, design guidelines and research gaps

Linbo Zhang, Mohamed A. Sultan
article en
2 citations

Abstract

Abstract The National Research Council Canada conducted two major fire resistance studies on floor assemblies over the past two decades. Despite the publication of the experimental results, there is a lack of suggested guidelines for design practitioners and gaps for future research. Thus, this paper comprehensively reviews the fire resistance results of 85 full‐scale floor tests, suggests design guidelines, and identifies research gaps. These efforts aim to enhance the understanding and support the potential improvement of the fire performance of floor assemblies. The review of the results covers the impact of various design parameters on the fire resistance of floor assemblies, such as framing type and spacing, insulation type, subfloor configuration, resilient channel spacing, number of gypsum board layers, and screw spacing from the board edge. Although the interaction of these factors is complex, some of them play significant roles in determining the overall fire resistance of floor assemblies. For instance, rock and cellulose insulation outperformed glass fibre, a wider resilient channel spacing lowered fire resistance, whilst an increased distance of screws from the board edge improved the fire resistance. More importantly, detailed explanations are provided for the influences these parameters exert on fire resistance. Following this detailed examination of the results, design guidelines are provided for practitioners' consideration. A comparison is made between the experimental results and predictions from the component additive methods in the Canadian and Euro Codes, demonstrating that both methods yield conservative results. Finally, this paper concludes by identifying research gaps and providing recommendations for future investigations, including the necessity of experimental studies on floor assemblies with new design configurations and the promising role of machine learning in fire resistance evaluation.

Fire and MaterialsVol. 49(1)
National Research Council Canada (CA)
Openalex Percentile: Top 35%
Fire effects on concrete materials
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.