Novel analytical approach for baclofen quantification in rodent plasma

A simple, accurate, and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantification of Baclofen in rat plasma. The method demonstrated high degree of linearity (r<sup>2</sup> = 0.9936) across a concentration range of 10-50 μg/mL. Precision, accuracy, limit of detection (LOD), limit of quantification (LOQ), and robustness were evaluated according to ICH guidelines. The LOD and LOQ were found to be 0.076197 and 0.23090 μg/mL, respectively. This method provides an efficient approach for Baclofen quantification in plasma, making it suitable for pharmacokinetic and bioavailability studies. The novelty of this study lies in its optimization for routine use in laboratories, ensuring reproducibility with minimal variations across different conditions and analysts.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2024-11-13
DOI
https://doi.org/10.1002/bmc.6038
Primary Topic
Botulinum Toxin and Related Neurological Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel analytical approach for baclofen quantification in rodent plasma

Anju Dhiman, Bindu Dhiman, Saurabh Satija, Mithlesh Yadav
Biomedical Chromatography
Botulinum Toxin and Related Neurological Disorders
article

Novel analytical approach for baclofen quantification in rodent plasma

Anju Dhiman, Bindu Dhiman, Saurabh Satija, Mithlesh Yadav
article en

Abstract

A simple, accurate, and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method was developed and validated for the quantification of Baclofen in rat plasma. The method demonstrated high degree of linearity (r<sup>2</sup> = 0.9936) across a concentration range of 10-50 μg/mL. Precision, accuracy, limit of detection (LOD), limit of quantification (LOQ), and robustness were evaluated according to ICH guidelines. The LOD and LOQ were found to be 0.076197 and 0.23090 μg/mL, respectively. This method provides an efficient approach for Baclofen quantification in plasma, making it suitable for pharmacokinetic and bioavailability studies. The novelty of this study lies in its optimization for routine use in laboratories, ensuring reproducibility with minimal variations across different conditions and analysts.

Biomedical ChromatographyVol. 39(1)
Lovely Professional University (IN), University of Wollongong (AU), Jodhpur National University (IN), Maharshi Dayanand University (IN)
Openalex Percentile: Top 68%
Botulinum Toxin and Related Neurological Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.