External Validation of Fully-Automated Infrarenal Maximum Aortic Aneurysm Diameter Measurements in Computed Tomography Angiography Scans Using Artificial Intelligence (PRAEVAorta 2)

This multicenter, retrospective validation study assessed the accuracy of fully-automated maximum infrarenal aortic aneurysm diameter measurements. It was demonstrated, that 95.4% of measurements were within the clinically acceptable range of 5 mm in absolute difference, positioning the software as a potential adjunct for clinical practice and research. It is also highlighted however, that critical review of the measurements is obligatory, due to a 10% segmentation error rate.

Authors

Institutions

Publication Details

Journal
Journal of Endovascular Therapy
Published
2024-11-13
DOI
https://doi.org/10.1177/15266028241295563
Citations
5
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
2.09

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

External Validation of Fully-Automated Infrarenal Maximum Aortic Aneurysm Diameter Measurements in Computed Tomography Angiography Scans Using Artificial Intelligence (PRAEVAorta 2)

Dierk Scheinert, Jonathan Fiering, Dittmar Böckler, Tilo Kölbel et al.
5 citations
Journal of Endovascular Therapy
Aortic aneurysm repair treatments
2.09
article

External Validation of Fully-Automated Infrarenal Maximum Aortic Aneurysm Diameter Measurements in Computed Tomography Angiography Scans Using Artificial Intelligence (PRAEVAorta 2)

Dierk Scheinert, Jonathan Fiering, Dittmar Böckler, Tilo Kölbel, Eric L.G. Verhoeven, Geert Lauwers, Hans van Overhagen, Barend Mees, Johannes Hatzl, Bram Fioole, Christian Uhl, Alexandru Barb, Αthanasios Katsargyris, Hugo T.C. Veger, Jan J. Wever, Edris El‐Sanosy, Kak Khee Yeung, Lukas C. van Dijk, Hubert Schelzig, Philippe W.M. Cuypers, Frank Vermassen, Randolph G. Statius van Eps, Wouter Van den Eynde, Guido Rouhani, Daniel J. Henning
article en
5 citations

Abstract

This multicenter, retrospective validation study assessed the accuracy of fully-automated maximum infrarenal aortic aneurysm diameter measurements. It was demonstrated, that 95.4% of measurements were within the clinically acceptable range of 5 mm in absolute difference, positioning the software as a potential adjunct for clinical practice and research. It is also highlighted however, that critical review of the measurements is obligatory, due to a 10% segmentation error rate.

Journal of Endovascular Therapy
Radboud University Nijmegen (NL), Heidelberg University (DE), Catharina Ziekenhuis (NL), University Hospital Heidelberg (DE), RWTH Aachen University (DE)
Dietmar Hopp Stiftung
Good health and well-being
Openalex Percentile: Top 12%
Aortic aneurysm repair treatments
2.09
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.