An Experimental Investigation of the Effect of Two-Phase Flow in a Manifold on Water Jet Lengths

The outlet flow rates and changes in behaviors of five outlet ports where water and air–water (two-phase) mixtures pass horizontally in a manifold pipe system were investigated experimentally. The effects of different air-flow rates, vacuumed from the atmosphere with a Venturi device in the system, on the outlet flow rates and diameters of the manifold port outlets were compared by measuring the outlet jet lengths. The system performance provided homogeneity of manifold port outlet flows and was tested. As a result, it was observed that homogeneous jet lengths were obtained in both single and two-phase low main manifold flows and equal outlet port diameters. When the main manifold flow rate V is 1.5–2 m/s, the system is stable and produces high jet lengths. The manifold pipe systems used in the experimental setup provide suitable working conditions for d/D = 0.433. The system does not show a smooth flow pattern with Venturi devices for d/D < 0.433. The low flow rates in this study’s tests are key. They are vital for designing micro irrigation systems. This depends on the critical d/D ratio of the system.

Authors

Institutions

Publication Details

Journal
Water
Published
2024-11-13
DOI
https://doi.org/10.3390/w16223263
Citations
1
Primary Topic
Irrigation Practices and Water Management
Type
article
Field-Weighted Citation Impact
0.33
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Experimental Investigation of the Effect of Two-Phase Flow in a Manifold on Water Jet Lengths

Tamer Bağatur, Şeyhmus Tümür, Arjin Ata
1 citations
Water
Irrigation Practices and Water Management
0.33
article

An Experimental Investigation of the Effect of Two-Phase Flow in a Manifold on Water Jet Lengths

Tamer Bağatur, Şeyhmus Tümür, Arjin Ata
article en
1 citations

Abstract

The outlet flow rates and changes in behaviors of five outlet ports where water and air–water (two-phase) mixtures pass horizontally in a manifold pipe system were investigated experimentally. The effects of different air-flow rates, vacuumed from the atmosphere with a Venturi device in the system, on the outlet flow rates and diameters of the manifold port outlets were compared by measuring the outlet jet lengths. The system performance provided homogeneity of manifold port outlet flows and was tested. As a result, it was observed that homogeneous jet lengths were obtained in both single and two-phase low main manifold flows and equal outlet port diameters. When the main manifold flow rate V is 1.5–2 m/s, the system is stable and produces high jet lengths. The manifold pipe systems used in the experimental setup provide suitable working conditions for d/D = 0.433. The system does not show a smooth flow pattern with Venturi devices for d/D < 0.433. The low flow rates in this study’s tests are key. They are vital for designing micro irrigation systems. This depends on the critical d/D ratio of the system.

WaterVol. 16(22)
Dicle University (TR)
Clean water and sanitation
Openalex Percentile: Top 33%
Irrigation Practices and Water Management
0.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.